分享
分销 收藏 举报 申诉 / 109
播放页_导航下方通栏广告

类型燃煤蒸汽电厂电气主辅机设备制造厂--电气主机运行手册.doc

  • 上传人:胜****
  • 文档编号:2653801
  • 上传时间:2024-06-03
  • 格式:DOC
  • 页数:109
  • 大小:1.82MB
  • 下载积分:10 金币
  • 播放页_非在线预览资源立即下载上方广告
    配套讲稿:

    如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。

    特殊限制:

    部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。

    关 键  词:
    燃煤 蒸汽 电厂 电气 主辅机 设备 制造厂 主机 运行 手册
    资源描述:
    SINOMACH – CNEEC – PENTA JOINT OPERATION PLTU 1 JAWA BARAT INDRAMAYU 3X330MW COAL FIRED POWER PLANT Electrical Operation Manual Document Number: SCP-OM-031 Revised Edition: 3 Owner: PT PLN Prepared by: EPC Contractor SCP JO September 20, 2010 106 序 言 Preface 本《电气运行手册》根据PLTU 1 JAWA BARAT INDRAMAYU 3X330MW 燃煤蒸汽电厂电气主辅机设备制造厂提供的设备使用维护说明书和相关图纸编制的,仅适用于本项目运行操作。 The Electric Operation Manual is prepared based on the O&M Instructions and relevant drawings provided by electric equipment manufacturers. It is only suitable for the operations in PLTU 1 JAWA BARAT INDRAMAYU 3X330MW COAL FIRED POWER PLANT PROJECT. 目 录 Contents 序 言 A PREFACE A 3.1 发-变组运行手册 1 3.1 OPERATION MANUAL OF GENERATOR-TRANSFORMER UNIT 1 3.1.1 范围 1 3.1.1 Scope 1 3.1.2 规范性引用文件 1 3.1.2 Specified reference 1 3.1.3 概述及技术规范 3 3.1.3 Overview and technical specifications 3 3.1.4 发-变组继电保护及同期装置 30 3.1.4 Generator-transformer unit relay protection and synchronization 30 3.1.5 发-变组的启动 47 3.1.5 Generator-transformer unit startup 47 3.1.6 发-变组的运行维护 62 3.1.6 Operation and maintenance of generator-transformer unit 62 3.1.7 发-变组的停止 79 3.1.7 Shutdown of generator-transformer unit 79 3.1.8 发-变组异常运行及事故处理 85 3.1.8 Abnormal operation and emergency treatment for generator -transformer 85 3.1 发-变组运行手册 3.1 Operation Manual of generator-transformer unit 3.1.1 范围 3.1.1 Scope 本运行手册规定了印尼INDRAMAYU 3×330MW 燃煤电站项目发电机组设备规范、机组启动、正常运行调整及维护、机组停运、事故处理、辅助设备运行操作和机组联锁保护试验等。 This O&M Manual covers the equipment Specifications, unit start-up, regulation and maintenance during normal operation, unit shutdown, trouble-shooting, operation of auxiliary Equip and interlock protection test of INDRAMAYU 3×330MW Coal-fired Power Plant. 本运行手册适用于印尼INDRAMAYU 3×330MW 燃煤电站项目汽轮发电机组设备、系统的运行和事故处理,凡从事该机组运行、检修及管理的人员均应熟悉或掌握本手册的全部或部分内容。 This manual is only suitable for operation, maintenance and trouble-shooting of the STG equipment, unit. Thus, any one that will join the operation, maintenance and management of this unit should be familiar with the whole or part of this manual. 3.1.2 规范性引用文件 3.1.2 Specified Reference 下列文件中的条款均是中国电力管理的相关文件,通过本手册的引用而成为本手册的条款。 Terms in the documents below, which are the relevant documents of Chinese Power Administration, have been quoted to be some items of this manual. 《防止电气误操作装置管理规定》 国家电网安监[2006]904号 Regulations to Prevent Incorrect Electrical Operations [2006] No.904 State Grid Safe Production Supervisory 《防止电气生产重大事故的二十五项重点要求》 国家电力公司[2000] 25 Requirements for Preventing Severe Accidents during Power Generation National Electrical Power Corporation [2000] 《发电机运行规程》 国电发[1999]579号 Regulation on Generator Operation National Electrical Power Co. [1999] No.579 《汽轮发电机技术条件》 SD 270—88 Technical Conditions of STG SD 270—88 《继电保护及安全自动装置运行管理规程》 (82)水电生字第11号 Regulations on Operation & Management of Relay Protections & Safe Automatic Devices (82) Hydraulic Power Generation No.11 《高压断路器运行规程》 电供[1991]30号 Regulation on HV Circuit Breaker Operation Utility (1991) No.30 《变电站运行导则》 DL/T 969-2005 Guideline on Sub-station Operation DL/T 969-2005 《电力变压器运行规程》 DL/T 572-95 Regulation on Electrical Transformer Operation DL/T 572-95 《电力电缆运行规程》 (79)电生字第53号 Regulation on Electrical Cable Operation Power Generation No.53 《电力设备预防性试验规程》 DL/T 596-1996 Regulation on Preventive Test for Electrical Equipment DL/T 596-1996 《电力系统用蓄电池直流电源装置运行及维护技术规程》 DL/T 724-2000 Regulation on Technology of O&M of DC Power Device of Batteries for Electrical System 《继电保护及安全自动装置运行管理规程》 西电调字(1993)7号 Regulations on Operation & Management of Relay Protections & Auto Safety Devices Western Power Dispatch No. 7 (1993) 《微机继电保护装置运行管理规程》 DL/T 587-96 Regulations on Operation & Management of Micro-computerized Relay Protection Device DL/T 587-96 《干式电力变压器技术参数和要求》 GB/T 10228-1997 Technical Parameters & Requirements of Dry-type Electrical Transformer GB/T 10228-1997 《干式电力变压器》 GB 6450-86 Dry-type Electrical Transformer GB 6450-86 《电业安全工作规程(发电厂和变电所电气部分)》 DL408-91 Power Industry Safety Code (Electrical Part of Power Plant & Sub-station) DL408-91 3.1.3 概述及技术规范 3.1.3 Overview and Technical Specifications 印度尼西亚INDRAMAYU电厂工程位于西爪哇省Indramayu Regency市Sukara区Sumuradem村,位于雅加达以东约180公里。 The Indramayu Project is constructed in Sumuradem village of Sukara district in the city of Indramayu Regency in Western Java and is located approximately 180km to the east of Jakarta. INDRAMAYU电厂安装3×330MW国产亚临界燃煤湿冷发电机组,电厂内设150KV配电装置,出4回线路接入印尼150KV系统。 3×330MW sub-critical coal-fired water cooling generation units are installed in Indramayu power plant where 150KV switchgear is equipped and four outgoing lines are connected with the 150KV system of Indonesia. 本工程燃用来自Sumatera和Kalimantan的煤炭,驳船运输进厂,厂内设煤码头。 The coal for this project comes from Sumatera and Kalimantan and is transported into the coal jetty with a barge in the power plant. 冷却系统采用海水直流冷却,冷却水取自爪哇海的海水。厂内设置海水淡化站,以海水淡化后的生水作为生活用水和锅炉补充用水。 The cooling system adopts seawater flow cooling for which the water is obtained from Java Sea. One water desalination station is available in the power plant and the treated water is used as the raw water for domestic water and water supply of boiler. 机组主要承担基本负荷,并具有一定的调峰能力(30%~90%范围)。 The units mainly carry the basic load and is capable of peak regulation in certain scope(30%~90%). 设备日利用小时数:20小时 Daily availability of equipment in hrs: 20h 设备年利用小时数:6000小时 Annual availability of equipment in hrs: 6000h 锅炉为北京巴布科克.威尔科克斯有限公司提供的1050t/h,亚临界压力、一次中间再热、单炉膛、自然循环、平衡通风、固态排渣、前后墙对冲燃烧、汽包型燃煤锅炉,露天布置,全钢构架。 The boiler in use, which is provided by Babcock & Wilcox Company, is designed in this way: it is of sub-critical pressure, primary intermediate reheating, single furnace, natural circulation, balanced ventilation, solid slag discharge, cross firing between the front and rear wall, steam drum coal-fired boiler, outdoor arrangement with a whole steel framework. 汽轮机由北京北重汽轮电机有限公司提供的330MW亚临界参数、一次中间再热、单轴三缸双排汽凝汽式汽轮机。型号:N330-17.75/540/540 The turbine, which is produced by Beijing Beizhong STG Corporation, is of 330MW sub-critical parameters, primary intermediate reheating. This condensate-type steam turbine is of primary intermediate reheating and has one single shaft, 3 casings and dual exhaust. Its model is N330-17.75/540/540. 发电机由北京北重汽轮电机有限公司提供的QFSN-350-2型自并励静止励磁、水-氢-氢冷却的发电机组。 The QFSN-350-2 generator provided by Beijing Beizhong STG Corporation is of self-shunt static excitation with H2O-H2-H2 cooling. 3.1.3.1 发-变组及自并励励磁系统概述及技术规范 3.1.3.1 Overview and Technical Specifications for generator-transformer unit and Self-shunt Excitation System 3.1.3.1.1 发电机-变压器组接线概述 3.1.3.1.1 General Description about Connection of generator-transformer unit 3台330MW汽轮发电机组,以发电机-变压器组单元接线型式接入厂内150KV配电装置。发电机出线端和中性点端的出线套管各装设4组电流互感器,发电机出线端配置3组电压互感器和1组避雷器,发电机中性点经单相接地变压器二次侧电阻接地。发电机与主变压器之间的连接采用全连式离相封闭母线,高压厂用变压器和励磁变压器由发电机与主变低压侧之间引接。发电机励磁采用静态自并励系统。 Three 330MW STG units are connected with the 150KV switchgear in form of generator-transformer unit. 4 CTs are installed at the busbar bushings on the generator outgoing side and neutral point side respectively. 3 PTs and 1 group of surge arresters are equipped on the generator outgoing side. The generator neutral point is earthed via a single transformer whose secondary side is connected with a shunt resistor; one end of the resistor is earthed. In addition, the generator is connected with the transformer with whole connection isolated-phase enclosed busbar and the HV auxiliary transformer as well as the excitation transformer is connected between the generator and the main transformer. The exciter adopts static self-shunt excitation system. 150KV配电装置采用采用3/2断路器接线方式,3台发电机组经主变压器升压接入150KV母线。全厂设置2台起动/备用变压器,作为电厂机组起动和备用电源,由150KV配电装置母线引接。设置1台150/20KV城市供电变压器(TFT)由150KV母线引接。150KV系统共有3回发-变组进线,2回起备变出线,1回TFT出线,4回线路出线,组成5个完整串。除过TFT外,所有变压器进线及出线回路均装设三相电压互感器,在150KV母线装设单相电压互感器。 The 150KV switchgear adopts two thirds CB connection and the 3 generators set are stepped up by 3 main power transformers and then connected to the 150KV busbar. 2 set of start-up/standby transformers are installed in the plant, serving as plant start-up and standby power source, which are connected from the 150KV busbar. One 150/20KV TFT is equipped, which is originated from the 150KV busbar for the 150KV system, there are totally 3 in-coming lines are available for generator-transformer unit, 2 outgoing lines for SST, one outgoing for TFT and 4 outgoing lines. Therefore, 5 complete incoming and outgoing loops are formed. Except the TFT, all the transformers are fitted with 3-phase PTs for in-coming and outgoing lines. Additional, single phase PTs are fitted for the 150KV busbar system. 150KV配电装置采用屋外中型布置型式,为了减小配电装置纵向尺寸,加长横向尺寸以利于变压器能够直接架空进线,断路器采用双列布置,每一串的进出线回路占用2个间隔。在母线的两端设置母线接地开关。 The 150KV switchgear adopts outdoor intermediate-type layout to decrease the vertical size and extent transverse size so that the transformer can be directly connected with the overhead in-coming. The CB is arranged in 2 columns and each bunch of in-coming and outgoing occupies 2 chambers. For each busbar, 2 earthing disconnectors are installed on the both ends. 3.1.3.1.2 发电机技术规范 3.1.3.1.2 Technical Specifications of Generator 发电机由北京北重汽轮电机有限公司提供的QFSN-350-2型自并励静止励磁、水-氢-氢冷却的发电机组。 The generator provided by Beijing Beizhong STG Corporation is of self-shunt static excitation, H2O-H2-H2 cooling. Its model is QFSN-350-2. 型号 T255-460(QFSN-350-2型) 额定电压 24KV 电压波动 ±5% 额定功率因数 0.85 额定功率 330MW 视在功率 388MVA 最大连续输出容量 347MVA 额定电流 9339A 额定转速 3000r/min 额定效率 98.85% 额定励磁电压 542V 额定励磁电流 2495A 相数 3相 极数 2极 额定频率 50Hz 稳态负序电流 I2/In=12% 暂态负序电流 (I2/In)2t=10s 励磁方式 机端自并励 定子绕组联接方式 Y/Y 绝缘等级 F级 生产厂家有限责任公司 北京北重汽轮电机 Model T255-460 (QFSN-350-2 Type) Rated Voltage 24KV Voltage Fluctuation ±5% Rated Power Factor 0.85 Rated Power 330MW Apparent Power 388MVA Max. Continuous Output 347MVA Rated Current 9339A Rated Rotation Speed 3000r/min Rated Efficiency 98.85% Rated Excitation Voltage 542V Rated Excitation Current 2495A 2495A Number of Phases 3 Number of Poles 2 Rated Frequency 50Hz Stable Negative Sequence Current I2/In=12% Transient Negative Sequence Current (I2/In)2t=10s Excitation Mode Self-shunt Excitation from Generator Side Stator Winding Connection Type Y/Y Insulation Level F Manufacturer Beijing Beizhong STG Corporation 3.1.3.1.3 发电机冷却系统规范 3.1.3.1.3 Technical Specifications for Generator Cooling System 发电机采用水-氢-氢的冷却方式,发电机定子绕组采用水内冷,转子绕组与定子铁芯采用氢气冷却方式。发电机内部为密闭循环通风系统,氢气由外部氢系统供给,并经发电机两侧的四个氢气冷却器冷却。定子线圈的冷却水由外部独立循环的内冷水系统供给。 The generator adopts H2O-H2-H2 cooling mode which means the stator windings are cooled by internal water, the rotor winding and stator core are cooled by H2. The inside of the generator is one sealed circulation ventilation system and H2, which is cooled by the 4 coolers at both ends of the generator, is filled into the generator by the external H2 system. In addition, the stator winding cooling water comes from the independent external circulative internal cooling water system. 3.1.3.1.3.1 定子绕组的冷却 3.1.3.1.3.1 Cooling of Stator Windings 冷却方式 直接冷却 冷却介质 除盐水 定子绕组水流量 60m3/h 出线端子水流量 9m3/h 定子绕组进口水温 <45℃ 定子绕组出口水温 <60℃ 定冷水导电率 <0.5ms/cm 定冷水PH值 7~8 定冷水硬度 <2×10-3mol/m3 定冷水机械杂质 <5mm 定冷水冷却器台数 4 冷却器冷却水流量 120t/h 冷却器冷却水入口温度 正常20℃ 最高33℃ 冷却器冷却水出口温度 正常28.7℃ 最高41.7℃ Cooling Mode Direct Cooling Cooling Medium Demineralized Water Water Flow in Stator Winding 60m3/h Water Flow at Outlet End 9m3/h Inlet Water Temp. of Stator Winding <45℃ Outlet Water Temp. of Stator Winding <60℃ Conductivity of Stator Cooling Water <0.5ms/cm PH of Stator Cooling Water 7~8 Hardness of Stator Cooling Water <2×10-3mol/m3 Mechanical Impurity of Stator Cooling Water <5mm Quantity of Stator Coolers 4 Water Flow of Stator Cooler 120t/h Inlet Water Temp. of Cooler 20℃ as normal 33℃ as Max. Outlet Water Temp. of Cooler 20℃ as normal 33℃ as Max. 3.1.3.1.3.2 定子铁芯和转子绕组的冷却 3.1.3.1.3.2 Cooling of Stator Core and Rotor Winding 冷却方式 表面冷却 冷却介质 H2 氢气压力 0.3MPa 氢气纯度 98% 氢气流量 36m3/h 氢冷器数量 4 布置方式 轴向 冷却器冷却水流量 325t/h 总冷却面积 736m2 冷却器冷却水额定温度 26.7℃ 冷却器冷却水最高温度 39.7℃ 水室压降 0.05Mpa(0.5bar) 冷氢温度 30℃(水温20℃) 43℃(水温33℃) 热氢温度 44℃(20℃) 57℃(水温33℃) Cooling Mode Surface Cooling Cooling Medium H2 H2 Pressure 0.3MPa H2 Purity 98% H2 Flow 36m3/h Quantity of H2 Coolers 4 Layout Axial Water Flow in Cooler 325t/h Total Cooling Area 736m2 Rated Temp. of Cooling Water of Cooler 26.7℃ Max. Temp. of Cooling Water 39.7℃ Pressure Drop of Water Chamber 0.05Mpa(0.5bar) Cold H2 Temp. 30℃(Water Temp. at 20℃) 43℃(Water Temp. at 33℃) Hot H2 Temp. 44℃(Water Temp. at 20℃) 57℃(Water Temp. at 33℃) 3.1.3.1.4 励磁系统概述及其技术规范 3.1.3.1.4 Overview & Technical Specifications of Excitation System #1、#2、#3发电机组励磁系统均采用自并励静止励磁系统,通过励磁变压器从发电机机端取得励磁电源,为高起始快速响应系统。随发电机配套体提供励磁设备,主要技术指标为: Static self-shunt excitation system is used for unit #1, #2 and #3. In this system, excitation power is obtained from the generator output via one excitation transformer and it is one quick responding system with high initiation. The excitation equipment is provided with the generator as a whole set. The parameters are shown as follows: 顶值电压倍数: ≥2.0 强励时间: ≥20s 响应时间: ≤0.1s (高起始响应) Peak Voltage Multiple: ≥2.0 Forced Excitation Duration: ≥20s Response time: ≤0.1s(High Initiation Response) 励磁系统主要由励磁变压器、励磁整流柜、磁场开关柜、发电机起励和励磁调节器柜等装置,以及监测、保护、报警辅助装置组成。 The excitation system consists of one excitation transformer, an excitation rectifier panel, a magnetic field CB panel, one AVR panel as well as devices such as monitor, protections and alarms. 3.1.3.1.4.1 励磁变压器 3.1.3.1.4.1 Excitation Transformer 励磁变压器采用励磁系统配套干式变压器,能满足机组正常运行及强励时的需要。满足发电机做空载、短路试验的需要,参数如下: One dry-type transformer, which is provided with the excitation system as a whole set, is used as the excitation transformer to meet the demand of normal unit operation and forced excitation. Also, needs of no-load test and short-circuit test can be satisfied. Parameters of this transformer are listed as follows: 型式 单相干式变压器组 容量 4313KVA 满载二次侧电流 3000A 满载二次侧电压 900V 额定电压 24/0.9KV 频率 50Hz 联结方式 Y,d11 阻抗 8.14% 冷却方式 自然风冷/强迫风冷 Type Single Phase Dry-type Transformer Capacity 4313KVA Full-load Current on Secondary Side 3000A Full-load Voltage on Secondary Side 900V Rated Voltage 24/0.9KV Frequency 50Hz Connection models Y,d11 Impedance 8.14% Cooling Mode Natural/Forced Air Cooling 3.1.3.1.4.2 励磁整流柜 3.1.3.1.4.2 Rectifier Panel for Excitation 可控硅整流装置并联可控硅元件有1/4并联支路退出运行时能满足发电机强励要求,有1/2并联支路退出运行时能保证发电机在额定工况下连续运行。 If 1/4 of the parallel thyristor elements of the rectifier are out of operation, the demand for forced excitation can still be satisfied; if 1/2 of the parallel thyristor elements are out of operation, the generator can operate under the ra
    展开阅读全文
    提示  咨信网温馨提示:
    1、咨信平台为文档C2C交易模式,即用户上传的文档直接被用户下载,收益归上传人(含作者)所有;本站仅是提供信息存储空间和展示预览,仅对用户上传内容的表现方式做保护处理,对上载内容不做任何修改或编辑。所展示的作品文档包括内容和图片全部来源于网络用户和作者上传投稿,我们不确定上传用户享有完全著作权,根据《信息网络传播权保护条例》,如果侵犯了您的版权、权益或隐私,请联系我们,核实后会尽快下架及时删除,并可随时和客服了解处理情况,尊重保护知识产权我们共同努力。
    2、文档的总页数、文档格式和文档大小以系统显示为准(内容中显示的页数不一定正确),网站客服只以系统显示的页数、文件格式、文档大小作为仲裁依据,个别因单元格分列造成显示页码不一将协商解决,平台无法对文档的真实性、完整性、权威性、准确性、专业性及其观点立场做任何保证或承诺,下载前须认真查看,确认无误后再购买,务必慎重购买;若有违法违纪将进行移交司法处理,若涉侵权平台将进行基本处罚并下架。
    3、本站所有内容均由用户上传,付费前请自行鉴别,如您付费,意味着您已接受本站规则且自行承担风险,本站不进行额外附加服务,虚拟产品一经售出概不退款(未进行购买下载可退充值款),文档一经付费(服务费)、不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。
    4、如你看到网页展示的文档有www.zixin.com.cn水印,是因预览和防盗链等技术需要对页面进行转换压缩成图而已,我们并不对上传的文档进行任何编辑或修改,文档下载后都不会有水印标识(原文档上传前个别存留的除外),下载后原文更清晰;试题试卷类文档,如果标题没有明确说明有答案则都视为没有答案,请知晓;PPT和DOC文档可被视为“模板”,允许上传人保留章节、目录结构的情况下删减部份的内容;PDF文档不管是原文档转换或图片扫描而得,本站不作要求视为允许,下载前可先查看【教您几个在下载文档中可以更好的避免被坑】。
    5、本文档所展示的图片、画像、字体、音乐的版权可能需版权方额外授权,请谨慎使用;网站提供的党政主题相关内容(国旗、国徽、党徽--等)目的在于配合国家政策宣传,仅限个人学习分享使用,禁止用于任何广告和商用目的。
    6、文档遇到问题,请及时联系平台进行协调解决,联系【微信客服】、【QQ客服】,若有其他问题请点击或扫码反馈【服务填表】;文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“【版权申诉】”,意见反馈和侵权处理邮箱:1219186828@qq.com;也可以拔打客服电话:0574-28810668;投诉电话:18658249818。

    开通VIP折扣优惠下载文档

    自信AI创作助手
    关于本文
    本文标题:燃煤蒸汽电厂电气主辅机设备制造厂--电气主机运行手册.doc
    链接地址:https://www.zixin.com.cn/doc/2653801.html
    页脚通栏广告

    Copyright ©2010-2025   All Rights Reserved  宁波自信网络信息技术有限公司 版权所有   |  客服电话:0574-28810668    微信客服:咨信网客服    投诉电话:18658249818   

    违法和不良信息举报邮箱:help@zixin.com.cn    文档合作和网站合作邮箱:fuwu@zixin.com.cn    意见反馈和侵权处理邮箱:1219186828@qq.com   | 证照中心

    12321jubao.png12321网络举报中心 电话:010-12321  jubao.png中国互联网举报中心 电话:12377   gongan.png浙公网安备33021202000488号  icp.png浙ICP备2021020529号-1 浙B2-20240490   


    关注我们 :微信公众号  抖音  微博  LOFTER               

    自信网络  |  ZixinNetwork