分享
分销 收藏 举报 申诉 / 29

类型RH-顶枪-Anlagen.pptx

  • 上传人:仙人****88
  • 文档编号:14770617
  • 上传时间:2026-11-18
  • 格式:PPTX
  • 页数:29
  • 大小:1.07MB
  • 下载积分:10 金币
  • 配套讲稿:

    如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。

    特殊限制:

    部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。

    关 键  词:
    RH Anlagen
    资源描述:
    Titelmasterformat durch Klicken bearbeiten,Textmasterformate durch Klicken bearbeiten,Zweite Ebene,Dritte Ebene,Vierte Ebene,Fnfte Ebene,16.03.2010,Nr.,Operation Instructions,Safety,management,of combustibles for the main burner,COG and fuel gas operating pressures are monitored with the13K4,13K5 und 13K7.The push-type switches are fitted on the“top lance system”.,In the event of higher or lower deviations,an error message is displayed via the 20P0 Text Panel.,The main burners three control checks make up the safety chain for the 13K8 safety relay.This safety relay must be enabled manually by the 13S9 button.,The start status is signalled potential free to the PLC.,In the event of a failure,an error message is signalled via the 18P2 light indicator.,“REMOTE”start,The“REMOTE”operating mode of the PLC-system burner control can be activated through the“burner start”command.The 11K1 and 14K1 safety controls switch on.,*The 13Y2 purge valve is opened and the 14K6 control protection applied to the voltage by the,uninitiated 14K2,time relay 14K2.The ignition burner is purged.,With the PLC“Purge on”,purging can independently be activated from“burner start”.,The,ignition burners pre-aeration time switches on when,Mixture control check is not switched off,23K2 control protection is enabled,purge control check is positive,12K3 control protection is enabled,.,In the event of purge control check failure before purge time completion,the time lapse is interrupted and an error message is displayed via the 20P0 text panel.,In this event,the failure status is signalled potential free to the PLC.,Once the purge time is completed,purging is interrupted.The ignition burners safety relay and safety chain are enabled.,See also ignition burner pressure enquiries,.,The natural gas 13Y0 solenoid valve is activated and the 13Y1 exhaust valve is closed.,The ignition burner is ready for use.,The start status is signalled potential free to the PLC,.,A failure of the safety chain relay after initiating purging is signalled optically via the 18H2 light indicator,.,“,LOCAL”start,The“LOCAL”operating mode of the burner control can be manually activated with the 14S82/143S83 push button when,No PLC emergency stop is enabled,11K6 safety relay is enabled,no,main burner failures exist,16K9 control protection disabled,mixture,control check is not switched off,23K2 control protection enabled.,When the release of the LOCAL operation is switched from the PLC,control protection 11K5 is activated,then any further operation will be as described from*under“REMOTE”.,In“LOCAL”operating mode,only the ignition burner may be started,the main burner switching mechanism is interrupted,.,Ignition,burner controls,The 15A0 control burner is ready for use.,The gas admission valve power supply is activated when,12K6 safety chain is,activated,or,remote,start or,local start(activated).,The,burner is activated when,12K6,safety chain is activated,pre-aeration has ended,14K5 activated,16K5,disconnection time has not elapsed.,The following control procedures are initiated at FDA5018:,15T1 Ignition transformer under tension,Gas admission valve 15Y4 and 15Y5 open,when no visible flame appears,ignition is repeated 3 times,The burner is ignited and the flame is monitored ionically,The control apparatus identifies the flame and switches to operation mode,15K7 switches,on,the,ignition burner is ignited,the operating status is signalled via the 18P6 light,indicator,the,power control intensity can be read in the display next to the control unit.,After the third failed ignition attempt or an extinguished flame during operation,the gas admission valves are switched off and an error message is signalled via the 18P7 light indicators and the 20P0 text panel.,The failure status is signalled potential free to the PLC,.,The burner failure must be manually unlocked with the 15S9 button or the PLC signal,.,Further details concerning the equipment can be found in the documentation.,Main,burner controls,The 16A0 control burner is ready for use.,The gas admission valve activation occurs when,mixture control check is not switched off,23K2 control protection enabled,13K8 safety chain enabled,The burner starts when,The gas admission valves are filled(prerequisite),or the ignition burner operation,15K7,is activated,or the main burner operation,16K6 is activated,burner start remote,14K1 activated,The burner LOCAL start,14K8 has not been terminated.,The following control procedures are initiated at PWA5013,Activation of natural gas and oxygen gas admission valves through the 16K6 safety chain,valves 17Y4,17Y5,17Y7 and 17Y8 are opened,exhaust valves 17Y6 and 17Y9 are closed,NOTE!,At,the same time,a control pulse of about 20”is activated with the 16K5 time relay and the flame failure device of the burner control unit,a flame will be simulated for a specified amount of time,the operation notification16K6 control protection and the 16K7 time relay for the ignition burners disconnection is activated,the operating status is signalled via the 18P8 light indicator,if there is no visible flame created during this time,the start sequence is aborted and the valves closed,the burner control unit reacts as if flame failure has occurred and reports the failure.,When the main burner is ignited,the flame is monitored by a 16B2 UV flame failure device,the burner stays on.,The 16K7 time relay expires after about 30 seconds,and the ignition burner is switched off.,In the event that the main burner is switched off before the 16K5 time relay lapses,or during the flame failure monitoring time,an error is generated through 16K9 and the 17K1 time delay drop out.,The 17K2 control protection enters self hold relay,the error message“Fault burner stop when bypass-time”is optically displayed via the light indicator and the text panel.,The failure status is signalled potential free to the PLC.,The failure must be unlocked with the 15S9 button.,In the event of flame failure,the activation of the gas admission valves is switched off and the failure is signalled via the 18P9 light indicator.,The failure status is signalled potential free as a burner failure to the PLC.,Further details concerning the equipment can be found in the documentation.,Indicator,light control,All indicator lights are accessed through the 18V0 diode gate.,A light test can be carried out using the 18S1 button.,Error notifications are signalled via flashing lights,the frequency is adjusted via the 18K9 relay.,COG,oxygen mixture control check,The main burners mixture control check is carried out via the 22P1 programmable multifunction unit.,The following values are read as 4-20mA signals:,COG flow 22B1,Oxygen flow22B2,COG pressure,Oxygen pressure,COG Temperature,Oxygen Temperature,A ratio is established that must be contained within the values of 2.05 to 2.80.,Monitoring is activated 60 seconds after“Main burner operation”.During operation,the ratio may be outside the perimeter values for less than 20mA),P_COG,pressure,CO-gas(100%-20mA),F_O2,flow,oxigen(100%-20mA),P_O2,pressure,oxigen(100%-20mA),Scale analog input(Temperature),Scale analog input(Temperature),COtmax,temperature,CO-gas max value(100%-20mA),COtmin,temperature,CO-gas min value(0%-40mA),O2tmax,temperature,oxigen max value(100%-20mA),O2tmin,temperature,oxigen min value(0%-40mA),Parameter,Parameter,P0_COGnorm pressure CO-gas,(,standard orifice),P0_O2norm pressure,oxygen,(,standard orifice),T0_COGnorm temperature CO-gas,(,standard orifice),T0_O2norm temperature oxygen,(,standard orifice),O2/COGlration oxygen/CO-gas low high limit,O2/COGhration oxygen/CO-gas high limit,Messages,on text panel,The following messages are displayed on the text panel,:,compressor fault,circuit,breaker 8Q1 switched off,Ignition burner gas pressure switch*p max*,Ignition burner gas pressure switch over maximum,pressure,Ignition burner air pressure switch*p min*,Ignition,burner air pressure switch under minimum pressure,Purging air flow switch*f,min*,Purging,air flow switch under minimum switching point,Enabled,during activation of purging valves,Time,delay 2,seconds,Messages on text panel,Ignition burner fault,Ignition burner fault,main burner gas pressure switch*p max*,gas pressure switch over maximum pressure,main burner fault,main burner fault,main burner stop when bypass time,In the event of the main burner switching off during bypass time,automatic breaker 230V AC off,automatic breaker 230VAC off,Messages on text panel,automatic breaker 24V DC off,automatic breaker 24VDC off,main burner oxygen pressure switch*p min*,oxygen pressure switch under minimum pressure,Oxygen/gas ratio failure,Oxygen/gas ratio failure,Local mode not released,Local mode pre-selected,but not released by PLC,All displays must be manually deleted when the failure is corrected.,User/operator acoustic and optical signals for failure or group notifications can be obtained on the X3 terminal strip.For loads see documentation.,Further details concerning the equipment and programming can be found in the documentation.,Burner,control to PLC signal exchange,The following signals are transmitted potential free to the PLC via the burner control:,ignition,burner ready for operation,ignition,burner safety chain operational,main,burner ready for operation,main,burner safety chain operational,ignition,burner running,ignition,burner running,signal from control unit via protection,15K7,ignition,burner fault,ignition,burner fault,signal from control unit via protection,15K8,main burner running,main burner running,signal from control unit via protection 16K6,Burner control to PLC signal exchange,main burner fault,main burner fault,signal from control unit via protection 16K9,or burner switched off before end of the overlap time 17K2.,ratio control release,release of main burner and ignition burner adjustment control again switched off.,ignition burner local operation on,ignition burner local operation on,signal from control unit via protection 14K9,purging air min.,purging air enquiries negative during purging,Oxygen/gas ratio failure,Oxygen gas ratio control switched,signal via protection 23K4,
    展开阅读全文

    开通VIP折扣优惠下载文档

    提示  咨信网声明:本文档由用户上传并分享,仅供学习交流、研究之用,未经授权,严禁复制、发行、汇编、翻译或网络传播等,侵权必究。

    咨信网小贴示:
    1、浏览或下载可查看了解,请点击【咨信网告知】。
    2、下载文件中如有侵权或不适当内容,将立即纠正。
    3、如果因为网速或其他原因下载失败请重新下载,重复下载[60天内]不扣币。
    4、开具发票登录电脑端申请,请点击【索取发票】。

    咨信网客服组:【微信客服】

    自信AI创作助手
    关于本文
    本文标题:RH-顶枪-Anlagen.pptx
    链接地址:https://www.zixin.com.cn/doc/14770617.html

    Copyright ©2010-2026   All Rights Reserved  宁波自信网络信息技术有限公司 版权所有   |  客服电话:0574-28810668    微信客服:咨信网客服    投诉电话:18658249818   

    违法和不良信息举报邮箱:help@zixin.com.cn    文档合作和网站合作邮箱:fuwu@zixin.com.cn    意见反馈和侵权处理邮箱:1219186828@qq.com   | 证照中心

    12321jubao.png12321网络举报中心 电话:010-12321  jubao.png中国互联网举报中心 电话:12377   gongan.png浙公网安备33021202000488号  icp.png浙ICP备2021020529号-1 浙B2-20240490   


    关注我们 :微信公众号  抖音  微博  LOFTER               

    自信网络  |  ZixinNetwork