分享
分销 收藏 举报 申诉 / 15
播放页_导航下方通栏广告

类型RevoMRISureScanPacemakerMedtronicCRDMDevicerevoMRIsurescan起搏器美敦力CRDM装置.pptx

  • 上传人:人****来
  • 文档编号:7353598
  • 上传时间:2024-12-31
  • 格式:PPTX
  • 页数:15
  • 大小:2.84MB
  • 下载积分:8 金币
  • 播放页_非在线预览资源立即下载上方广告
    配套讲稿:

    如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。

    特殊限制:

    部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。

    关 键  词:
    RevoMRISureScanPacemakerMedtronicCRDMDevicerevoMRIsurescan 起搏器 美敦力 CRDM 装置
    资源描述:
    Click to edit Master title style,Click to edit Master text styles,Second level,Third level,Fourth level,Fifth level,#,The First and Only Pacing SystemFDA Approved for MRI Use,Specifically engineered for MRI safety,with reliable lead technology and a proven pacemaker platform this is state-of-the-art pacing.,Now your patients get proven cardiac care with MRI access.,Meeting the Need for MRI,Pacemaker Implants in an Aging Population,The number of pacemakers currently implanted in the United States is approximately 1.5 million,1,2,Elderly patients are the primary users of MRI:individuals over age 65 are,twice as likely,to need an MRI compared to younger recipients.,3,Average Age of Pacemaker Patient,13%,Ages 25-64,86%,Age 65+,1,Kalin R,Stanton MS.,PACE,.2005;28:326-328.,2,Zhan C,et al.,Gen Intern Med,.2008;23:13-19.,3,Global Industry Analysts,Inc.Magnetic Resonance Imaging(MRI)Equipment a global strategic business report.San Jose,CA.2002.,Part of Comprehensive Patient Care,Now,for the first time,you can implant a state-of-the-art pacing system to provide proven cardiac care AND MRI access when your patients need it,Number of Comorbidities in Pacemaker Patients,Given that 85%of all pacemaker patients have one or more comorbidities,facilitating comprehensive multispecialty care is important in todays environment,Medical and Surgical Specialties Rely on,MRI for Diagnosis,Your choice can affect their decisions and diagnostic capabilities,15%,0 comorbidities,30%,1 comorbidity,28%,2 comorbidities,27%,3 or more,comorbidities,Opthalmology,Otolaryngology,Neurosurgery,Neurology,Cardiothoracic Surgery,Surgical Oncology,Nephrology,Gynecologic Oncology,Urology,Rheumatology,Oncology,Radiation Oncology,Interventional Radiology,Gastrointestinal Surgery,Orthopedic Surgery,Vascular Surgery,85%,1,1 or more,comorbidities,1,Kalin R,Stanton MS.,PACE,.2005;28:326-328.,Prevalence of Common Comorbiditiesin the Pacemaker Patient Population,The Prevalence of Common Comorbidities Increases Rapidly Over Age 65.,1-3,MRI Is the Gold Standard Diagnostic Tool for,Neurologists,Oncologists,and Orthopedic Surgeons,Whose Patients Are Often Over 65 Years of Age.,4,MRI is unmatched in its ability to accurately visualize soft tissue,It is estimated that 50 to 75%of pacemaker patients will have a medical need for an MRI over the lifetime of their device,5,The Most Common Reasons for MRI Referral Are,Musculoskeletal and Neurological Symptoms.,6,Medicare records show that in patients 65 years of age with,an implanted pacemaker:,34%have spine and intervertebral disc disease,7,36%have chronic pain of wrist,foot,ankle,or elbow,7,14%suffer from injury or trauma to the spine,knee,or shoulder,7,1,National Cancer Institute April 2009.US estimated complete prevalence(including counts)by age on 1/1/2006.Based on November 2008 SEER data submission;DCCPS,Surveillance Research Program,Statistical Research and Applications Branch.,2,Lawrence RC,et al.,Arthritis Rheum,.1998;41:778-799.,3,American Heart Association.Heart Disease and Stroke Statistics 2010 Update:,Learn and Live,.Prevalence of stroke by age and sex(NHANES:2003-2006).,4,Magnetic Resonance Imaging(MRI)Equipment A global Strategic Business Report,Global Industry Analysts,Inc.,San Jose,CA 2002.,5,Kalin R,Stanton MS.,PACE,.2005;28:326-328.,6,Medical Imaging Survey,2009.,7,Medicare Fee-for-Service Review,2007.,Field,Impact,Static,Gradient,RF,Lead Heating,The conductive pacing lead acts as an antenna,picking up radiofrequency energy.A portion of this energy is dissipated as heat in the cardiac tissue near the tip electrode.,Tissue damage may affect pacing therapy.,Unintended Cardiac Stimulation,The gradient and radiofrequency fields will induce voltages in pacemaker leads that will be applied to the pacing lead electrodes.If these voltage pulses are large enough,they may directly stimulate the heart.,May lead to a single or intermittent stimulation,or sustained tachycardia.,Device Interactions,The gradient,radiofrequency,and static fields may adversely affect the electrical operation of the pacemaker system if its operation is not protected from the effects of those fields.,Pacemaker malfunction or failure may affect pacing therapy.,Hazards and Risks of MRI with Current Pacing Systems,Since 2008,the safety and risk concerns of MRIs in cardiac device patients have been documented in 17 studies.,1-17,MRI can put pacemaker patients at risk for any of the following,16,:,1,Naehle CP,et al.,Pacing Clin Electrophysiol,.2009;32:1526-1535.,2,Goldsher D,et al.,Pacing Clin Electrophysiol,.2009;32:1355-1356.,3,Gimbel JR.,Europace,.2009;11:1241-1242.,4,Naehle CP,et al.,J Am Coll Cardiol,.2009;54:549-555.,5,Roguin A.,J Am Coll Cardiol,.2009;54:556-557.,6,Mollerus M,et al.,Pacing Clin Electrophysiol.,2008;31:1241-1245.,7,Pulver AF,et al.,Pacing Clin Electrophysiol,.2009;32:450-456.,8,Nordbeck P,et al.,Magn Reson Med,.2009;61:570-578.,9,Sutton R,et al.,Trials,.2008;9:68.,10,Naehle CP,et al.,Radiology,.2008;249:991-1001.,11,Calcagnini G,et al.,J Magn Reson Imaging,.2008;28:879-886.,12,Dyrda K,Khairy P.,Expert Rev Cardiovasc Ther,.2008;6:823-832.,13,Gimbel JR.,Pacing Clin Electrophysiol,.2008;31:795-801.,14,Nordbeck P,Bauer WR.,Dtsch Med Wochenschr.,2008;133:624-628.Article in German.,15,Tandri H,et al.,Heart Rhythm,.2008;5:462-468.,16,Roguin A,et al.,Circulation,.2004;110:475-482.,17,Medtronic,Inc.EnRyhthm MRI SureScan Pacing System Clinical Report,in support of FDA premarket approval.,MR Conditional Risk Information,A complete SureScan pacing system including a Revo MRI SureScan IPG and two CapSureFix MRI SureScan leads is required for use in the MRI environment,Any other pacing system combination may result in a hazard to the patient during an MRI scan,When programmed to On,the MRI SureScan feature allows the patient to be safely scanned while the device continues to provide appropriate pacing,Refer to the Revo MRI Pacing System Conditions for Use located in the device manuals prior to scanning a patient.Consult Medtronics website at,or call Medtronic at 1(800)328-2518.,Specifically Engineered for MRI Safety,Device Design Solutions,Input circuits optimized,Circuit design immune to interference,SureScan,Pacing Mode,Asynchronous pacing,High pacing outputs,The Revo MRI SureScan pacing system has completed clinical evaluation,regulatory review,and FDA approval;it is safe for use when used according to the MRI conditions for use as defined in the SureScan manual,The implanted system must consist solely of a Medtronic Revo MRI SureScan Model RVDR01 device and two CapSureFix MRI,SureScan Model 5086 MRI leads,Revo MRI SureScan Pacemaker ,A Pacemaker Engineered with Multiple Safety Features,Device verification appears on pacemaker programmer screen,Automatic testing ensures only appropriate battery and impedance data are collected during MRI,Dedicated programming mode provides additional security/backup for power on reset(POR),Hall sensor is immune to strong magnetic fields,Easily Identifiable,Radiopaque Icon Confirms SureScan Device Implant,Specifically Engineered for MRI Safety,Lead Heating Design Solution,Lead inner conductor coil design mitigates lead heating,4 filar to 2 filar increases inductance and reduces heating,Materials identical to 5076*,Model 5086MRI lead flex testing,Connector/body,Lead body,Model 5086MRI clinical implant experience starting February 2007(928 leads implanted),*Exception of MRI Marker band and,electrode coating,CapSureFix MRI,SureScan,Lead Model 5086,A Lead Designed for MRI Use,The state-of-the-art 5086 lead is specifically designed and engineered for safety within an MRI environment,The 5086 lead is based on the CapSureFix,family of leads,which have been implanted in more than 1 million patients worldwide thats 2.5 million leads,with 99.5%reliability,Easily Identifiable,Radiopaque Icon Confirms SureScan Device Implant,Lead HeatingModel 5076 versus Model 5086 MRI,the x-axis represents 50 anatomically relevant lead paths,the results demonstrate significant variability in lead tip heating as a function of the lead path,overall the 5086 MRI lead heats approximately 3 times less than the 5076 for most lead paths,Preclinical Research Demonstrates the Safety of Revo MRI,Pacing System,1,Testing Summary,Extensive preclinical evaluation was based on clinically relevant as well as worst-case scan conditions,using in vitro(bench)testing,in vivo(animal)testing,and computer simulations(modeling).,MRI-Induced Lead Heating,Simulations in Human Body Models Using Different Lead Combinations,Human body models encompassed 2nd to 97th percentile of all human bodies,with ten different lead paths,Over 400,000 different lead/body combinations were analyzed to derive a minimal probability of a 0.5 V threshold,Human Body Library,Lead Paths,1,Magnetic Resonance Imaging(MRI)Equipment a global strategic business report,Global Industry Analysts,Inc.San Jose,CA.2002.,MRI-Induced Unintended Cardiac Stimulation(UCS),Analysis combined a prediction for the induced voltage pulse widths and amplitudes,and an in-vivo canine study to evaluate the stimulation threshold to these pulses,The risk of reaching the gradient stimulation range is 1/1,000,000,which remains outside the capture range,Results confirmed that patient risk from UCS is at an acceptable level,Gradient Stimulation Strength Duration Curve,Study Design,Multicenter,randomized,controlled clinical trial designed to evaluate the safety of the Revo MRI SureScan Pacing System,including any MRI-related complications,as well as to analyze pacing capture thresholds and sensing amplitude,464 patients received a SureScan pacing system and were then randomized to elective MRI or no MRI,approximately 9-12 weeks post-implant,MRI imaging intended to represent commonly used,clinically relevant scans,Methods Visit Schedule,Clinical Trial Demonstrates the Safetyof Revo MRI,SureScan,1,1,Medtronic,Inc.EnRyhthm MRI SureScan Pacing System Clinical Report,in support of FDA premarket approval.,Clinical Trial Demonstrates the Safetyof Revo MRI,SureScan,1,Key Results,100%were free of MRI-related complications(n=211,P 0.001),No sustained atrial or ventricular arrhythmias,no asystole,no pacemaker output inhibition,and no electrical resets in the group receiving MRI,Minimal changes in pacing capture thresholds,as shown on the following chart,Primary Effectiveness End Point:Atrial and Ventricular Capture Threshold,Threshold changes pre-MRI/control visit to 1-month post-MRI/control visit,1,Medtronic,Inc.EnRyhthm MRI SureScan Pacing System Clinical Report,in support of FDA premarket approval.,Builds Upon Medtronic Innovations,MVP,Managed Ventricular Pacing,Exclusive technology that uses atrial pacing(AAIR)primarily,with DDD(R)pacing only when necessary,MVP reduces unnecessary RV pacing by 99%,1,ACC/AHA/HRS guidelines,2,state the need to reduce unnecessary pacing as much as possible.The following studies support the guidelines:,MOST,3,:,Every incremental 1%of unnecessary VP increases the risk for heart failure hospitalizations by 5.4%,and for AF,by 1%.,Danish II,4,:,Even with long AV delays,the risk of AF doubles with DDD(R)pacing compared to AAI(R)with DDD(R)backup.,Gardiwal,5,:,Patients with 72%RV pacing are at increased risk for VT/VF.,Medtronic CareLink,Network*,The leading Internet-based,remote monitoring service for implanted devices,6,Serving nearly 500,000 patients in 3,000 clinics in the United States,*Not all devices are available on the CareLink,Network,1,Gillis AM,et al.,Heart Rhythm,.2005.Abstract AB21-1.,2,Epstein AE,et al.,J Am Coll Cardiol,.2008;51:e1-62.,3,Sweeney MO,et al.,Circulation,.2003;10:2932-2937.,4,Nielsen JC,et al.,J Am Coll Cardiol,.2003;42:614-623.,5,Gardiwal A,et al.,Europace,.2008;10:358-363.,6,Medtronic CareLink Metrics Database.,Revo MRI Pacing System Conditions for Use,A complete SureScan,pacing system including a Revo MRI SureScan,IPG and two SureScan leads is required for use in the MRI environment.,Any other combination may result in a hazard to the patient during an MRI,scan.The SureScan feature must be programmed to On prior to scanning a,patient according to the specified conditions for use.,Cardiology requirements:,Patients and their implanted systems must be screened to meet the following requirements:,No previously implanted(active or abandoned)medical devices,leads,lead extenders,or lead adaptors,No broken leads or leads with intermittent electrical contact,as confirmed by lead impedance history,A SureScan pacing system that has been implanted for a minimum of 6 weeks,A SureScan pacing system implanted in the left or right pectoral region,Pacing capture thresholds of 2.0 volts(V)at a pulse width of 0.4 milliseconds(ms),A lead impedance value of 200 ohms()and 1,500,No diaphragmatic stimulation at a pacing output of 5.0 V,and at a pulse width of 1.0 ms in patients whose device will be programmed to an asynchronous pacing mode when the MRI SureScan is on,Radiology requirements:,Horizontal,cylindrical bore magnet,clinical MRI systems with a static magnetic field of 1.5 Tesla(T)must be used,Gradient systems with maximum gradient slew rate performance per axis of 200 Teslas per meter per second(T/m/s)must be used,The scanner must be operated in Normal Operating mode:,The whole-bodyaveraged specific absorption rate(SAR)must be 2.0 watts per kilogram(W/kg),The head SAR must be 3.2 W/kg,The patient must be positioned within the bore such that the isocenter(center of the MRI bore)is superior to the C1 vertebra or inferior to the T12 vertebra,Proper patient monitoring must be provided during the MRI scan.The methods include visual and verbal contact with the patient,electrocardiography,and pulse oximetry(plethysmography).,Training requirements:,A health professional who has completed cardiology SureScan training must be present during the programming of the SureScan feature,A health professional who has completed radiology SureScan training must be present during the MRI scan,Brief Statement,The Revo MRI SureScan,pacing system is MR Conditional and as such is designed to allow patients to undergo MRI under the specified conditions for use.,Indications,The Revo MRI SureScan Model RVDR01 IPG is indicated for use as a system consisting of Medtronic Revo MRI SureScan IPG implanted with two CapSureFix MRI,SureScan 5086MRI leads.A complete system is required for use in the MRI environment.,The Revo MRI SureScan Model RVDR01 IPG is indicated for the following:,Rate adaptive pacing in patients who may benefit from increased pacing rates concurrent with increases in activity,Accepted patient conditions warranting chronic cardiac pacing include:,Symptomatic paroxysmal or permanent second-or third-degree AV block,Symptomatic bilateral bundle branch block,Symptomatic paroxysmal or transient sinus node dysfunctions with or without associated AV conduction disorders,Bradycardia-tachycardia syndrome to prevent symptomatic bradycardia or some forms of symptomatic tachyarrhythmias,The device is a
    展开阅读全文
    提示  咨信网温馨提示:
    1、咨信平台为文档C2C交易模式,即用户上传的文档直接被用户下载,收益归上传人(含作者)所有;本站仅是提供信息存储空间和展示预览,仅对用户上传内容的表现方式做保护处理,对上载内容不做任何修改或编辑。所展示的作品文档包括内容和图片全部来源于网络用户和作者上传投稿,我们不确定上传用户享有完全著作权,根据《信息网络传播权保护条例》,如果侵犯了您的版权、权益或隐私,请联系我们,核实后会尽快下架及时删除,并可随时和客服了解处理情况,尊重保护知识产权我们共同努力。
    2、文档的总页数、文档格式和文档大小以系统显示为准(内容中显示的页数不一定正确),网站客服只以系统显示的页数、文件格式、文档大小作为仲裁依据,个别因单元格分列造成显示页码不一将协商解决,平台无法对文档的真实性、完整性、权威性、准确性、专业性及其观点立场做任何保证或承诺,下载前须认真查看,确认无误后再购买,务必慎重购买;若有违法违纪将进行移交司法处理,若涉侵权平台将进行基本处罚并下架。
    3、本站所有内容均由用户上传,付费前请自行鉴别,如您付费,意味着您已接受本站规则且自行承担风险,本站不进行额外附加服务,虚拟产品一经售出概不退款(未进行购买下载可退充值款),文档一经付费(服务费)、不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。
    4、如你看到网页展示的文档有www.zixin.com.cn水印,是因预览和防盗链等技术需要对页面进行转换压缩成图而已,我们并不对上传的文档进行任何编辑或修改,文档下载后都不会有水印标识(原文档上传前个别存留的除外),下载后原文更清晰;试题试卷类文档,如果标题没有明确说明有答案则都视为没有答案,请知晓;PPT和DOC文档可被视为“模板”,允许上传人保留章节、目录结构的情况下删减部份的内容;PDF文档不管是原文档转换或图片扫描而得,本站不作要求视为允许,下载前可先查看【教您几个在下载文档中可以更好的避免被坑】。
    5、本文档所展示的图片、画像、字体、音乐的版权可能需版权方额外授权,请谨慎使用;网站提供的党政主题相关内容(国旗、国徽、党徽--等)目的在于配合国家政策宣传,仅限个人学习分享使用,禁止用于任何广告和商用目的。
    6、文档遇到问题,请及时联系平台进行协调解决,联系【微信客服】、【QQ客服】,若有其他问题请点击或扫码反馈【服务填表】;文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“【版权申诉】”,意见反馈和侵权处理邮箱:1219186828@qq.com;也可以拔打客服电话:0574-28810668;投诉电话:18658249818。

    开通VIP折扣优惠下载文档

    自信AI创作助手
    关于本文
    本文标题:RevoMRISureScanPacemakerMedtronicCRDMDevicerevoMRIsurescan起搏器美敦力CRDM装置.pptx
    链接地址:https://www.zixin.com.cn/doc/7353598.html
    页脚通栏广告

    Copyright ©2010-2026   All Rights Reserved  宁波自信网络信息技术有限公司 版权所有   |  客服电话:0574-28810668    微信客服:咨信网客服    投诉电话:18658249818   

    违法和不良信息举报邮箱:help@zixin.com.cn    文档合作和网站合作邮箱:fuwu@zixin.com.cn    意见反馈和侵权处理邮箱:1219186828@qq.com   | 证照中心

    12321jubao.png12321网络举报中心 电话:010-12321  jubao.png中国互联网举报中心 电话:12377   gongan.png浙公网安备33021202000488号  icp.png浙ICP备2021020529号-1 浙B2-20240490   


    关注我们 :微信公众号  抖音  微博  LOFTER               

    自信网络  |  ZixinNetwork