1、Hilton International Specifications Copyright - Sept 2005 1 Lift traffic handling capability, ride quality and reliability. Performance Traffic handling standards are based on Hilton standards and not necessarily general market standards. Ride quality consists of two elements, noise and vibration, w
2、hich are essential to provide the comfort expected of Hiltons guests. In car noise and door operation noise are of particular importance, as is the vibration of the lift. Ride quality criteria should not be limited to guests lifts, and be applied to the back of house lifts as well. Escalators should
3、 operate quietly, as well as the step and handrail vibration being kept to a minimum. Reliability of all equipment is measured by uptime availability on a per unit monthly basis. Architectural finishes will be dependent on the particular property and will be detailed by the architectural design team
4、 and approved by Hilton International Technical Services. HILTON INTERNATIONAL GUIDELINES FOR HOTELS Strategic Performance Specification for lifts, escalators and loading bay equipment Hilton International Specifications Copyright - Sept 2005 5 GENERAL CONSIDERATIONS In addition to the technical asp
5、ects to be considered when selecting lift and escalator equipment, the following points should be taken into account when designing the systems to efficiently serve a hotel: - The size of the city, and location of the hotel in relation to it, the number of guest rooms and the hotel type (large conve
6、ntion, resort or tourist etc). The quantities and gross size of the public areas (function rooms, restaurants, health clubs, parking and retail etc.), their locations within the building, and the number of levels away from ground level. These factors will significantly affect the performance require
7、ments of the vertical transportation system. The adequacy of lifts for room service, kitchen service, housekeeping and maintenance, needs along with the handling of furniture, convention display boards and other equipment. Hotel guests should not have to climb stairways or ramps in order to reach li
8、fts or escalators, but where the building design makes this necessary the rise should be limited to a maximum of 1.20 m. Provision for disabled access should be borne in mind in these situations. To accommodate guests unable to use stairs and those who cannot comfortably use escalators, all public l
9、evels are to be accessible by lifts that have controls fully suitable for disabled passengers. A separate lift may be necessary for this purpose. Function rooms, major dining rooms and other public areas where large concentrations of people move to and from these areas at the same time should prefer
10、ably be located on the main lobby level. If this cannot be accomplished, they should be located only one floor above or below the main lobby level. HILTON INTERNATIONAL GUIDELINES FOR HOTELS Strategic Performance Specification for lifts, escalators and loading bay equipment Hilton International Spec
11、ifications Copyright - Sept 2005 6 When public areas have to be located above the main lobby level, a decision has to be made about whether they are to be accessed by the main guest lifts or escalators. If the guest lifts are to be used, the design of the lift system and the number of guest lifts th
12、at must incorporate security control has to be considered. Resident guests should not be subjected to undue waiting times as a result of heavy demand from the public areas, nor should they be at risk from unauthorized persons accessing the guest floors. For control and security, passenger lifts that
13、 serve the guest floors should only originate from the main lobby level. Additional shuttle lifts or escalators should then be used to serve underground parking levels, retail and other public areas. This will reduce the risk of unauthorized public access to guest floors. All lifts shall be connecte
14、d to the central fire monitoring system and have automatic circuits to ground the equipment in the event of fire. Passenger lift cars should be designed to create an atmosphere of being roomy, smooth and reliable, a seamless transition from the main lobby. Use of glass and mirrors, good lighting, TV
15、 screens for information and smooth operation add to the guest experience. For further guidance refer to Hilton International Technical Services. HILTON INTERNATIONAL GUIDELINES FOR HOTELS Strategic Performance Specification for lifts, escalators and loading bay equipment Hilton International Specif
16、ications Copyright - Sept 2005 7 PERFORMANCE CRITERIA The following criteria should be used when calculating the number of lifts needed to provide the level of quality service required within Hilton Internationals 4 and 5 star hotels. This applies both to passenger lifts and back of house service li
17、fts. The ratio of Back of House lifts to Guest lifts should be 50-75%. The number of Car Park lifts should be calculated by the number of car bays provided and based upon one passenger per car or in the case of a convention hotel this should be increased to two passengers per car. Escalator nominal
18、handling capacity with 1000mm wide steps at a speed of 0.5 m/s is 375 people per 5 minutes, or 4500 people per hour. For convention halls escalators should be considered as an efficient means of moving delegates both up and down, assuming the convention halls are one or two floors away from the grou
19、nd floor main lobby. Key data should be provided in order to calculate the traffic performance. This data should be obtained from all stakeholders, and normally would include the following;- number of rooms per floor, floor sizes, floor heights, hotel use ( convention, resort, commercial), special u
20、se floors such as fitness centers/pools, car park levels, basements and use, location of restaurants and table covers including times of opening, security requirements, staff access points, convention hall size and population. The following calculations need to be completed in order to design the ri
21、ght lift system appropriate for the individual hotel. Round Trip Time (RTT) is the time a lift will take to travel from the main entrance to the upper floors and back again, taking due account of passenger loading and unloading. It is measured conventionally as the average time between each arrival
22、of cars at the main floor. Handling Capacity is defined as the maximum number of passengers that a system can move within a five-minute period. It is determined by the size and quantity of cars and lift speed, with other factors such as acceleration, deceleration, door operation and system control l
23、ogic, which also influences its value. Interval has the most impact on the quality of service to passengers, i.e. how long they must wait for a lift. It is calculated as the average RTT divided by the number of lifts in a group. It is also determined by the size and quantity of cars and elevator spe
24、ed, with other factors such as HILTON INTERNATIONAL GUIDELINES FOR HOTELS Strategic Performance Specification for lifts, escalators and loading bay equipment Hilton International Specifications Copyright - Sept 2005 8 acceleration, deceleration, door operation and system control logic, which also in
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- 希尔顿电梯设计要求 Lift Specification 希尔顿 电梯 设计 要求
1、咨信平台为文档C2C交易模式,即用户上传的文档直接被用户下载,收益归上传人(含作者)所有;本站仅是提供信息存储空间和展示预览,仅对用户上传内容的表现方式做保护处理,对上载内容不做任何修改或编辑。所展示的作品文档包括内容和图片全部来源于网络用户和作者上传投稿,我们不确定上传用户享有完全著作权,根据《信息网络传播权保护条例》,如果侵犯了您的版权、权益或隐私,请联系我们,核实后会尽快下架及时删除,并可随时和客服了解处理情况,尊重保护知识产权我们共同努力。
2、文档的总页数、文档格式和文档大小以系统显示为准(内容中显示的页数不一定正确),网站客服只以系统显示的页数、文件格式、文档大小作为仲裁依据,平台无法对文档的真实性、完整性、权威性、准确性、专业性及其观点立场做任何保证或承诺,下载前须认真查看,确认无误后再购买,务必慎重购买;若有违法违纪将进行移交司法处理,若涉侵权平台将进行基本处罚并下架。
3、本站所有内容均由用户上传,付费前请自行鉴别,如您付费,意味着您已接受本站规则且自行承担风险,本站不进行额外附加服务,虚拟产品一经售出概不退款(未进行购买下载可退充值款),文档一经付费(服务费)、不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。
4、如你看到网页展示的文档有www.zixin.com.cn水印,是因预览和防盗链等技术需要对页面进行转换压缩成图而已,我们并不对上传的文档进行任何编辑或修改,文档下载后都不会有水印标识(原文档上传前个别存留的除外),下载后原文更清晰;试题试卷类文档,如果标题没有明确说明有答案则都视为没有答案,请知晓;PPT和DOC文档可被视为“模板”,允许上传人保留章节、目录结构的情况下删减部份的内容;PDF文档不管是原文档转换或图片扫描而得,本站不作要求视为允许,下载前自行私信或留言给上传者【super****30541】。
5、本文档所展示的图片、画像、字体、音乐的版权可能需版权方额外授权,请谨慎使用;网站提供的党政主题相关内容(国旗、国徽、党徽--等)目的在于配合国家政策宣传,仅限个人学习分享使用,禁止用于任何广告和商用目的。
6、文档遇到问题,请及时私信或留言给本站上传会员【super****30541】,需本站解决可联系【 微信客服】、【 QQ客服】,若有其他问题请点击或扫码反馈【 服务填表】;文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“【 版权申诉】”(推荐),意见反馈和侵权处理邮箱:1219186828@qq.com;也可以拔打客服电话:4008-655-100;投诉/维权电话:4009-655-100。