类型计算电流及需要系数表.xls

  • 上传人:Fis****915
  • 文档编号:535552
  • 上传时间:2023-11-23
  • 格式:XLS
  • 页数:5
  • 大小:38KB
  • 下载积分:5 金币
  • 播放页_非在线预览资源立即下载上方广告
    配套讲稿:

    如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。

    特殊限制:

    部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。

    关 键  词:
    计算 电流 需要 系数
    资源描述:
    1#1#楼楼计计算算负负荷荷及及配配电电干干线线表表序号供电区域名称装设功率(kW)需要系数(KX)计算功率Pjs(kW)无功功率Qjs(kvar)视在功率Sjs(kVA)功率因数COStan整定电流(A)计算电流(A)干线线径配电箱编号备注1区排烟、加压送风83.901.000.800.75200159.302(ZR-EE-4*120+70)双电源切换(消防电源)2、区排烟、加压送风62.201.000.800.75200118.102(ZR-EE-4*120+7)双电源切换(消防电源)3消防值班室12.901.0012.9012.130.730.946338.102(ZR-EE-4*+)双电源切换4消防水泵放71.101.000.800.75200137.602(ZR-EE-4*120+70)双电源切换(消防电源)5(区)消防电梯40.000.208.006.000.800.751002(ZR-EE-4*+)双电源切换6区电梯40.000.208.006.000.800.751002(ZR-EE-4*+)双电源切换7区电梯24.800.204.963.720.800.75632(ZR-EE-4*+)双电源切换8区电梯20.000.204.003.000.800.75632(ZR-EE-4*+)双电源切换9人防设备20.000.800.75632(ZR-EE-4*+)双电源切换(消防电源)10网络机房设备、照明129.200.81104.65100.460.720.96315226.002(ZR-EE-4*+)双电源切换11网络机房空调、锅炉房应急排风201.600.71143.14107.360.800.75350271.80(ZR-EE-4*120+70)个回路、每个回路根线(双电源切换)12间、分配线间26.601.0026.2025.150.720.968058.202(ZR-EE-4*+)双电源切换13冷水机组214.001.00214.00132.680.850.62500382.502(ZR-EE-4*1+)14冷水机组214.001.000.850.62500382.502(ZR-EE-4*1+)备用15 设备房、锅炉房255.600.98250.49180.350.810.72630475.302(ZR-EE-4*+)非双电源16生活水泵房33.800.9532.1124.080.800.758061.20ZR-EE-4*+两用一备17地下一层插座、照明33.200.6019.9215.540.790.786342.70ZR-EE-4*+第 1 页,共 5 页18区照明114.700.90103.2349.550.900.48315204.30ZR-EE-4*+19区插座282.200.70197.54201.490.701.02630430.802(ZR-EE-4*+)20区新风机组、风机盘管63.901.0063.9047.930.800.75200126.30ZR-EE-4*120+7021区照明74.200.9066.7832.050.900.48200140.50ZR-EE-4*120+7022区插座165.500.77127.44129.990.701.02350278.102(ZR-EE-4*120+70)23区新风机组、风机盘管36.601.0036.6027.450.800.7512570.80ZR-EE-4*+24区一层照明、插座、新风机组、风机盘管39.300.8834.5824.900.810.7210074.00ZR-EE-4*+25区二层照明、插座、新风机组、风机盘管36.800.8732.0222.410.820.7010067.20ZR-EE-4*+26区三五层照明、插座、新风机组、风机盘管76.400.8766.4747.860.810.72200140.90ZR-EE-4*120+70合计2372.501556.931200.10取KP=KQ=0.901401.241080.091769.2 自然功率因数:COS1=1401.24/1769.20=0.79,tan1=0.78经无功补偿后功率因数COS2=0.90,tan2=0.48,无功补偿容量QC=Pjs(tan1-tan2)=1401.24(0.78-0.48)=420.37kvar659.721548.78如无功补偿500kvar1401.24580.091516.570.921#1#楼楼计计算算负负荷荷及及配配电电干干线线表表序号供电区域名称装设功率(kW)需要系数(KX)计算功率Pjs(kW)无功功率Qjs(kvar)视在功率Sjs(kVA)功率因数COStan整定电流(A)计算电流(A)干线线径配电箱编号备注第 2 页,共 5 页电力负荷需要系数序号负荷名称需要系数(KX)功率因数COStan序号负荷名称需要系数(KX)功率因数COStan1总负荷0.450.800.7513送风机0.700.800.752总电力负荷0.550.800.7514热泵新风机0.501.000.003总照明负荷0.400.850.6215冷源机组0.750.800.754制冷机房0.650.800.7516照明0.850.900.485锅炉房0.650.750.8817办公插座0.100.701.026水泵房0.650.800.7518IT0.600.800.757通风机房0.650.800.7519UPS0.800.800.758电梯0.200.800.7520起重机0.150.501.739厨房0.400.701.0221通风机0.750.800.7510洗衣机房0.300.701.0222水泵电动机0.800.800.7511窗式空调器0.400.801.0223连续运输机械0.650.750.8812MAU0.750.801.0224冷源机组等0.750.5013生活给水泵0.750.8025普消泵0.750.8014排污泵0.750.8026喷淋泵0.750.8015冷却塔水泵0.750.8027消防电梯0.200.5016送风机0.700.8028U PS0.800.8017空调机组0.700.8029应急电源1.000.9018热泵新风机组0.501.0030施工机械需要系数序号负荷名称需要系数(KX)功率因数COStan序号负荷名称需要系数(KX)功率因数COStan1塔吊0.300.501.737降水泵0.800.701.022混泥土输送泵0.700.701.028卷扬机0.800.701.023闪光对焊机0.350.701.029冷拉机0.800.701.024竖焊机0.700.451.9810弯曲机0.800.701.025电焊机0.350.601.3311木工机械0.700.701.026振动泵0.800.701.0212照明1.001.000.00一期工程临电施工负荷计算表序号设备名称设备台数设备装设功率(PS)需要系数(KX)功率因数COStan有功功率(Pjs)无功功率(Qjs)视在功率(Sjs)备注1裁板机13.000.750.750.882.251.982钢筋弯曲机412.000.800.701.029.609.793钢筋切断机39.000.650.750.886.755.944卷扬机215.000.800.701.0212.0012.245平板振动器22.800.700.701.021.962.006插入式振动器1011.000.800.701.028.806.167加压泵26.000.600.701.023.603.678砼输送泵190.000.700.701.0263.0064.269砼搅拌机412.000.650.750.887.806.8610塔吊131.000.300.501.739.3016.0911砼搅拌站160.000.550.800.7588.0066.0012对焊机181.000.350.601.3328.3537.7113交流电焊机252.000.350.601.3318.2024.2114电渣压力机2146.000.350.601.3351.1067.9615照明20.000.400.850.628.004.96合计35650.80318.71329.83456.65 取kPp=0.9,kQq=0.9286.84296.85412.80自然功率因数COS1=Pjs1/Sjs1=286.84/412.8=0.69,tan1=1.05,经无功补偿后功率因数达到COS2=0.9,tan2=0.48,则补偿容量Qc=Pjs1*(tan1-tan2)=286.84*(1.05-0.48)=163.50kvar,则补偿后的总视在功率:Sjs2=(Pjs12+QjS22)=(286.842+(296.85-163.50)2)=316.32kVA。故选择315kVA的变压器。pjs=sjscos,Qjs=pjstan
    展开阅读全文
    提示  咨信网温馨提示:
    1、咨信平台为文档C2C交易模式,即用户上传的文档直接被用户下载,收益归上传人(含作者)所有;本站仅是提供信息存储空间和展示预览,仅对用户上传内容的表现方式做保护处理,对上载内容不做任何修改或编辑。所展示的作品文档包括内容和图片全部来源于网络用户和作者上传投稿,我们不确定上传用户享有完全著作权,根据《信息网络传播权保护条例》,如果侵犯了您的版权、权益或隐私,请联系我们,核实后会尽快下架及时删除,并可随时和客服了解处理情况,尊重保护知识产权我们共同努力。
    2、文档的总页数、文档格式和文档大小以系统显示为准(内容中显示的页数不一定正确),网站客服只以系统显示的页数、文件格式、文档大小作为仲裁依据,个别因单元格分列造成显示页码不一将协商解决,平台无法对文档的真实性、完整性、权威性、准确性、专业性及其观点立场做任何保证或承诺,下载前须认真查看,确认无误后再购买,务必慎重购买;若有违法违纪将进行移交司法处理,若涉侵权平台将进行基本处罚并下架。
    3、本站所有内容均由用户上传,付费前请自行鉴别,如您付费,意味着您已接受本站规则且自行承担风险,本站不进行额外附加服务,虚拟产品一经售出概不退款(未进行购买下载可退充值款),文档一经付费(服务费)、不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。
    4、如你看到网页展示的文档有www.zixin.com.cn水印,是因预览和防盗链等技术需要对页面进行转换压缩成图而已,我们并不对上传的文档进行任何编辑或修改,文档下载后都不会有水印标识(原文档上传前个别存留的除外),下载后原文更清晰;试题试卷类文档,如果标题没有明确说明有答案则都视为没有答案,请知晓;PPT和DOC文档可被视为“模板”,允许上传人保留章节、目录结构的情况下删减部份的内容;PDF文档不管是原文档转换或图片扫描而得,本站不作要求视为允许,下载前可先查看【教您几个在下载文档中可以更好的避免被坑】。
    5、本文档所展示的图片、画像、字体、音乐的版权可能需版权方额外授权,请谨慎使用;网站提供的党政主题相关内容(国旗、国徽、党徽--等)目的在于配合国家政策宣传,仅限个人学习分享使用,禁止用于任何广告和商用目的。
    6、文档遇到问题,请及时联系平台进行协调解决,联系【微信客服】、【QQ客服】,若有其他问题请点击或扫码反馈【服务填表】;文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“【版权申诉】”,意见反馈和侵权处理邮箱:1219186828@qq.com;也可以拔打客服电话:0574-28810668;投诉电话:18658249818。

    开通VIP折扣优惠下载文档

    自信AI创作助手
    关于本文
    本文标题:计算电流及需要系数表.xls
    链接地址:https://www.zixin.com.cn/doc/535552.html
    页脚通栏广告

    Copyright ©2010-2026   All Rights Reserved  宁波自信网络信息技术有限公司 版权所有   |  客服电话:0574-28810668    微信客服:咨信网客服    投诉电话:18658249818   

    违法和不良信息举报邮箱:help@zixin.com.cn    文档合作和网站合作邮箱:fuwu@zixin.com.cn    意见反馈和侵权处理邮箱:1219186828@qq.com   | 证照中心

    12321jubao.png12321网络举报中心 电话:010-12321  jubao.png中国互联网举报中心 电话:12377   gongan.png浙公网安备33021202000488号  icp.png浙ICP备2021020529号-1 浙B2-20240490   


    关注我们 :微信公众号  抖音  微博  LOFTER               

    自信网络  |  ZixinNetwork