分享
分销 收藏 举报 申诉 / 157
播放页_导航下方通栏广告

类型欧姆龙e5ck温控仪说明书.pdf

  • 上传人:曲****
  • 文档编号:13304499
  • 上传时间:2026-02-26
  • 格式:PDF
  • 页数:157
  • 大小:11.12MB
  • 下载积分:12 金币
  • 播放页_非在线预览资源立即下载上方广告
    配套讲稿:

    如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。

    特殊限制:

    部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。

    关 键  词:
    欧姆 e5ck 温控 说明书
    资源描述:
    E5CK Process ControllerUser ManualCat.No,H78-E3-2Notice:OMRON products are manufactured for use according to proper procedures by a qualified operator and only for the purposes described in this manual.The following conventions are used to indicate and classify precautions in this manual.Always heed the information provided with them.Failure to heed precautions can result in injury to people or damage to the product.DANGER!Indicates information that,if not heeded,is likely to result in loss of life or serious injury.WARNING Indicates information that,if not heeded,could possibly result in loss of life or serious injury./Caution Indicates information that,if not heeded,could result in relatively serious or minor injury,damage to the product,or faulty operation.OMRON Product ReferencesAll OMRON products are capitalized in this manual.The word“Unit”is also capitalized when it refers to an OMRON product.The abbreviation“Ch,which appears in some displays and on some OMRON products,often means“word”and is abbreviated“Wd”in documentation in this sense.The abbreviation TCn means Programmable Controller and is not used as an abbreviation for anything else.OMRON,1996,Rev.1998All rights reserved.No part of this publication may be reproduced,stored in a retrieval system,or transmitted,in any form,or by any means,mechanical,electronic,photocopying,recording,or otherwise,without the prior written permission of OMRON.No patent liability is assumed with respect to the use of the information contained herein.Moreover,because OMRON is constantly striving to improve its high-quality products,the information contained in this manual is subject to change without notice.Every precaution has been taken in the preparation of this manual.Nevertheless,OMRON assumes no responsibility for errors or omissions.Neither is any liability assumed for damages resulting from the use of the information contained in this publication.Visual AidsThe following headings appear in the left column of the manual to help you locate different types of information.Note Indicates information of particular interest for efficient and convenient operation of the product.1,2,3 1.Indicates lists of one sort or another,such as procedures,checklists,etc.How to Read Display SymbolsThe following tables show the correspondence between the E5CK display symbols and alphabet characters.The Reference MarkThis mark indicates that extra,useful information is being provided,such as supplementary explanations and how to apply functions.iiiContentsSECTION 1Introduction1-1 Nomenclature.21-1-1 Main Parts.21-1-2 Front Panel.21-1-3 About the E5CK.31-1-4 E5CK Displays.31-1-5 Basic Operations Using Keys.31-2 Input and Output.41-2-1 Input.41-2-2 Output.51-3 Parameters and Menus.61-3-1 Parameter Types.61-3-2 Selecting Modes.81-3-3 Selecting Parameters.91-3-4 Writing the Settings to Memory.91-4 Communications Function.91-5 Calibration.10SECTION 2Preparations2-1 Setting Up.122-1-1 Remove Internal Mechanism from the Housing.122-1-2 Setting the Input Type.122-1-3 Setting Up the Output Unit.132-1-4 Setting Up the Option Unit.132-2 E5CK Installation.142-2-1 Before Installing the E5CK.142-2-2 Dimensions.152-2-3 Panel Cutout.162-2-4 Installation Procedure.162-3 Wiring Terminals.172-3-1 Terminal Arrangement.172-3-2 Wiring Precautions.172-3-3 Wiring Procedure.18ivSECTION 3 Preparations3-1 Control Example.223-1-1 Setup.223-1-2 Input Type Connector.223-2 Setting Input Specifications.233-2-1 Input Type.233-2-2 Scaling.233-2-3 Input Shift.233-3 Setting Output Specifications.253-3-1 Output Assignments.253-3-2 Direct/Reverse Operation.263-3-3 Control Period.263-4 Setting Alarm Type.283-4-1 Alarm type.283-4-2 Alarm Value.293-4-3 Alarm Hysteresis.293-4-4 Close In Alarm/Open In Alarm.303-5 Protect Mode.323-5-1 Security.323-5-2 A/M Key Protect.333-6 Starting and Stopping Operation.333-6-1 Manipulated Variable at Stop.343-7 Adjusting Control Operation.343-7-1 Changing the Set Point.343-7-2 Manual Operation.353-7-3 Auto-tuning.36SECTION 4Applied Operation4-1 Selecting the Control Method.404-1-1 Heating and Cooling Control.404-1-2 ON/OFF Control.414-2 Operating Condition Restrictions.424-2-1 Manipulated Variable Restrictions.424-2-2 Set Point Limiter.454-2-3 SP Ramp.454-3 Using Option Functions.474-3-1 Event Input.474-3-2 Transfer Output.484-4 LBA.494-5 Calibration.514-5-1 Calibrating Thermocouple.534-5-2 Calibrating Platinum Resistance Thermometer.574-5-3 Calibrating Current Input.594-5-4 Calibrating Voltage Input.604-5-5 Checking Indication Accuracy.63SECTION 5Parameters5-1 Protect Mode.675-2 Manual Mode.685-3 Level 0 Mode.695-4 Level 1 Mode.735-5 Level 2 Mode.805-6 Setup Mode.865-7 Expansion Mode.945-8 Option Mode.1005-9 Calibration Mode.104SECTION 6Using the Communications Function6-1 Outline of the Communications Function.1066-1-1 Outline.1066-1-2 Transfer Procedure.1066-1-3 Interface.1066-2 Preparing for Communications.1076-2-1 Cable Connections.1076-2-2 Setting the Communications Specifications.1086-3 Command Configuration.1096-4 Commands and Responses.1106-4-1 Reading/Writing Parameters.1106-5 How to Read Communications Error Information.1146-6 Program Example.1176-6-1 How to Use Programs.1176-6-2 Program List(Language:IBM PC COMPATIBLE MACHINE).1186-6-3 Examples of Use.119SECTION 7Troubleshooting7-1 Initial Checks.1227-2 How to Use Error Display.1227-3 How to Use Error Output.1247-4 Checking Operation Restrictions.125APPENDIXSpecifications.129Control Block Diagram.132Parameter Operations List.133Fuzzy Self-Tuning.134Model List.137X Format.138ASCII Code List.141Setting List.142Calibration Mode.144viAbout this Manual:To ensure correct use,thoroughly read and understand this manual before using the E5CK.TopicManual LocationType of InformationFeatures of the E5CKSection 1-IntroductionFeatures of the E5CK,names of parts,and typical functions.Set UpSection 2-PreparationsOperations such as installation,wiring and switch settings you must do before using the E5CK.Basic E5CK OperationsSection 3-Basic OperationSection 5-ParametersHow to use the front panel keys and how to view the display when setting the parameters of the major E5CK functions.Applied E5CK OperationsSection 4-Applied OperationSection 5-ParametersImportant functions of the E5CK and how to use the parameters for full use of the E5CK.Communications with a Host ComputerSection 6-Using the Communications FunctionCommunications commands,and program examples.CalibrationSection 4-Applied OperationHow the user should calibrate the E5CK.TroubleshootingSection 7-TroubleshootingWhat to do if any problems occur.ixSECTION 1 IntroductionThis Section introduces the E5CK.For details on how to use the controller and how to work with parameter settings,refer to Section 2 and subsequent Sections.1-1 Nomenclature.21-1-1 Main Parts.21-1-2 Front Panel.21-1-3 About the E5CK.31-1-4 E5CK Displays.31-1-5 Basic Operations Using Keys.31-2 Input and Output.41-2-1 Input.41-2-2 Output.51-3 Parameters and Menus.61-3-1 Parameter Types.61-3-2 Selecting Modes.81-3-3 Selecting Parameters.91-3-4 Writing the Settings to Memory.91-4 Communications Function.91-5 Calibration.10NomenclatureSection 1-11-1 Nomenclature1-1-1 Main PartsTerminals国肉!*E5CK-AA1-302 model displays an auto-tune button instead of the key2NomenclatureSection 1-11-1-3 About the E5CK Select from many types of temperature and analog input(multiple input)Select output functions such as control output or alarm(output assignment)Use two set points(multi-SP function)Monitor the control loop by LBA(Loop Break Alarm)Use the communications function Calibrate input or transfer output Rely on the E5CK water-tight construction(NEMA 4:equivalent to IP66)1-1-4 E5CK DisplaysNo.1 DisplayDisplays the process value or parameter symbols.No.2 DisplayDisplays the set point,manipulated variable or parameter settings.Operation Indicators OUT 1 Lit when control output 1 is ON.OUT2 Lit when control output 2 is ON.SUB1 Lit when the output function assigned to auxiliaryoutput 1 is ON.MANU Lit when the manual operation mode is being used.STOP Lit when control operation has been stopped.RMT Lit during remote operation.AT Flashes during auto-tuning.1-1-5 Basic Operations Using Keys key keyEach press of this key switches between the auto and manual operations.Note:E5CK-AA1-302 models do not have the keY-Instead,they feature an auto-tune key.controls are in place within the programming.)cp|keyThe functions of this key change according to how long it is pressed.Pressing this key for less than one second,lets you scroll through the parameters within the mode.Pressing this key for one second or more,brings up the the menu display and allows you to select which mode you need to adjust.In key operations from here on,press the key indicates that you must press the key for less than one second.For details on parameter switching and menu display items,refer to Parameters and Menus in Section 1.西 keyEach press of the|key increments or advances the values or settings on the No.2 display,while each press of the 3 key decrements or returns the values or settings on the No.2 display.Some keys have more than one use.For example,when the 丨丨 key is held down simultaneously with the display key,or a key is held down continuously.For details,see Selecting Modes in Section 1.Also,refer to examples(using various key combinations)in Sections 3 and 4.3Input and OutputSection 1-21-2 Input and Output1-2-1 InputThe E5CK supports four different types of inputs.Temperature Input/Voltage Input/Current InputOnly one of these inputs can be selected and connected to the controller:Temperature input Voltage input Current inputNote:The above figure shows temperature input connected to the controller.The following input sensors can be connected for temperature input:Thermocouple:K,J,T,E,L,U,N,R,S,B,W,PLII Platinum resistance thermometer:JPtlOO,Pt 100The following currents can be connected for current input:4 to 20 mA,0 to 20 mAThe following voltages can be connected for voltage input:1 to 5 VDC,Oto 5 VDC,0 to 10 VDC4Input and OutputSection 1-2Event InputWhen using event input,add on the Input Unit E53-CKB.Select from the following five event inputs:Multi-SP Run/Stop Auto/Manual1-2-2 OutputThe E5CK supports these four outputs.Control output 1 Control output 2 Auxiliary output 1 Transfer outputWhen using control outputs 1 and 2,set the output unit(sold separately).Eight output units are available to suit the output circuit configuration.When using transfer output,add on the Transfer Output Option Board E53-CKF.Note:The output functions of the E5CK do not operate for five seconds after the E5CK is turned ON.Output AssignmentsThe E5CK supports the following eight output functions.Control output(heat)Control output(cool)Alarms 1 to 3 LBA Error 1(input error)Error 2(A/D converter error)Assign these output functions to control outputs 1 and 2 and auxiliary output 1.Two guidelines are:Only control output(heat),control output(cool),alarms 1 to 3,and LBA can be assigned to control outputs 1 and 2.Only alarms 1 to 3,LBA,and errors 1 and 2 can be assigned to auxiliary output 1.In the example given in Section 1-2(previous page),control output(heat)is assigned to control output 1;alarm 1 is assigned to control output 2;and,alarm 2 is assigned to auxiliary output 1.In this configuration,heating control output is connected to control output 1;and,alarm output is connected to control output 2 and auxiliary output 1.In a heating and cooling control,assign control output(cool)to either control output 1 or control output 2.Parameters and MenusSection 1-3Transfer OutputThe E5CK supports the following five transfer outputs.Set point Set point during SP ramp Process value Heating side manipulated variable Cooling side manipulated variableThese transfer outputs can be output after being scaled.Reverse scaling is also possible because setting an upper limit value smaller than the lower limit value is allowed.1-3 Parameters and Menus1-3-1 Parameter TypesE5CK parameters are distributed between the following nine modes.Protect mode Manual mode Level 0 mode Level 1 mode Level 2 mode Setup mode Expansion mode Option mode Calibration modeThe settings of parameters in each of seven modes(excluding the protect mode and manual mode)can be checked and modified by selection on the menu display.Protect ModeLimits use of the Menu and Keys.The protect function prevents unwanted modification of parameters and can also be used to prevent switching between the auto and manual operation.Manual ModeSets the controller to manual operation mode.You can only manually adjust the manipulated variable(MV)in this mode.Level 0 ModeFor normal operation.Change:the set point during operation,and start or stop Controller operation;and,(only in this mode)monitor the process value,ramp SP,and manipulated variable.Level 1 ModeFor adjusting primary control parameters.Execute:AT(auto-tuning);set alarm values;set the control period;and,set PID parameters.Level 2 ModeFor adjusting secondary control parameters.Set parameters for:limiting the manipulated variable and set point;switch6Parameters and MenusSection 1-3between the remote and local modes;set the loop break alarm(LBA),alarm hysteresis,and the digital filter value of inputs.Setup ModeFor setting the basic specifications.Set parameters for:input type,scaling,output assignments and direct/reverse operation.Expansion ModeFor setting expanded functions.Set:ST(self-tuning),SP setting limiter.Select:advanced PID or ON/OFF control.Specify the standby sequence resetting method.Initialize parameters;and,set the time for automatic return to the monitoring display.Option ModeFor setting option functions.Set:the communications conditions;transfer:output and event input parameters to match the type of Option Board installed in the Controller.This mode will be accessible_only when an option board is installed in the controller.Calibration ModeFor calibrating inputs and transfer output.Calibrate the selected input type.Transfer output can be calibrated only when the Transfer Output Option Board E53-CKF has been installed in the Controller.Menu DisplayTo select the menu display in any of the above modes(excluding the protect mode and manual mode),press the 花目 key for 1 second minimum.If you select the desired mode using the|为 or 13 keys and press the key,the top parameter in the specified mode is displayed.1线 2MWhen you have selected the menu display,the previous mode is selected.For example,if you selected the menu display while in the level 0 mode,the No.2 display changes to L u-0 as shown on the left.Protected modes cannot be selected.Also,the menu display does not appear when modes are protected up to the level 1 mode.Level 0 to 2 ModesIf you select Lu-D Lu-/or Lu-?in the menu display,the level 0,level 1 and level 2 modes,respectively,are selected.These modes are selected with control still continuing.Setup Mode Expansion Mode Option Mode Calibration modeIf you select SEE E6PE or f L b in the me
    展开阅读全文
    提示  咨信网温馨提示:
    1、咨信平台为文档C2C交易模式,即用户上传的文档直接被用户下载,收益归上传人(含作者)所有;本站仅是提供信息存储空间和展示预览,仅对用户上传内容的表现方式做保护处理,对上载内容不做任何修改或编辑。所展示的作品文档包括内容和图片全部来源于网络用户和作者上传投稿,我们不确定上传用户享有完全著作权,根据《信息网络传播权保护条例》,如果侵犯了您的版权、权益或隐私,请联系我们,核实后会尽快下架及时删除,并可随时和客服了解处理情况,尊重保护知识产权我们共同努力。
    2、文档的总页数、文档格式和文档大小以系统显示为准(内容中显示的页数不一定正确),网站客服只以系统显示的页数、文件格式、文档大小作为仲裁依据,个别因单元格分列造成显示页码不一将协商解决,平台无法对文档的真实性、完整性、权威性、准确性、专业性及其观点立场做任何保证或承诺,下载前须认真查看,确认无误后再购买,务必慎重购买;若有违法违纪将进行移交司法处理,若涉侵权平台将进行基本处罚并下架。
    3、本站所有内容均由用户上传,付费前请自行鉴别,如您付费,意味着您已接受本站规则且自行承担风险,本站不进行额外附加服务,虚拟产品一经售出概不退款(未进行购买下载可退充值款),文档一经付费(服务费)、不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。
    4、如你看到网页展示的文档有www.zixin.com.cn水印,是因预览和防盗链等技术需要对页面进行转换压缩成图而已,我们并不对上传的文档进行任何编辑或修改,文档下载后都不会有水印标识(原文档上传前个别存留的除外),下载后原文更清晰;试题试卷类文档,如果标题没有明确说明有答案则都视为没有答案,请知晓;PPT和DOC文档可被视为“模板”,允许上传人保留章节、目录结构的情况下删减部份的内容;PDF文档不管是原文档转换或图片扫描而得,本站不作要求视为允许,下载前可先查看【教您几个在下载文档中可以更好的避免被坑】。
    5、本文档所展示的图片、画像、字体、音乐的版权可能需版权方额外授权,请谨慎使用;网站提供的党政主题相关内容(国旗、国徽、党徽--等)目的在于配合国家政策宣传,仅限个人学习分享使用,禁止用于任何广告和商用目的。
    6、文档遇到问题,请及时联系平台进行协调解决,联系【微信客服】、【QQ客服】,若有其他问题请点击或扫码反馈【服务填表】;文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“【版权申诉】”,意见反馈和侵权处理邮箱:1219186828@qq.com;也可以拔打客服电话:0574-28810668;投诉电话:18658249818。

    开通VIP折扣优惠下载文档

    自信AI创作助手
    关于本文
    本文标题:欧姆龙e5ck温控仪说明书.pdf
    链接地址:https://www.zixin.com.cn/doc/13304499.html
    页脚通栏广告

    Copyright ©2010-2026   All Rights Reserved  宁波自信网络信息技术有限公司 版权所有   |  客服电话:0574-28810668    微信客服:咨信网客服    投诉电话:18658249818   

    违法和不良信息举报邮箱:help@zixin.com.cn    文档合作和网站合作邮箱:fuwu@zixin.com.cn    意见反馈和侵权处理邮箱:1219186828@qq.com   | 证照中心

    12321jubao.png12321网络举报中心 电话:010-12321  jubao.png中国互联网举报中心 电话:12377   gongan.png浙公网安备33021202000488号  icp.png浙ICP备2021020529号-1 浙B2-20240490   


    关注我们 :微信公众号  抖音  微博  LOFTER               

    自信网络  |  ZixinNetwork