分享
分销 收藏 举报 申诉 / 208
播放页_导航下方通栏广告

类型旭化成血透机MDS101_使用手册.pdf

  • 上传人:曲****
  • 文档编号:12592111
  • 上传时间:2025-11-07
  • 格式:PDF
  • 页数:208
  • 大小:12.81MB
  • 下载积分:15 金币
  • 播放页_非在线预览资源立即下载上方广告
    配套讲稿:

    如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。

    特殊限制:

    部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。

    关 键  词:
    化成 血透机 MDS101_ 使用手册
    资源描述:
    Single Patient Dialysis SystemMDS-101Operation ManualBefore using the product,please read this manual carefully,and thoroughly understand its operation.This manual should be kept in a safe place.MM3-00648-00 2009.9Table of Contents1 Before Using the System.1-21.1 Intended Purpose and Scope of Use.1-21.2 Applicable Standards.1-21.3 Product Specifications.1-31.4 Required Facilities and Environmental Conditions.1-81.5 Assembly,Installation,Setup and Adjustment.1-91.6 Part Names.1-101.6.1 External appearance.1-101.6.2 Operation panel.1-121.7 Operation Modes and Screen Navigation.1-131.8 Operation of the Display.1-141.8.1 Current process.1-151.8.2 Comment window.1-151.8.3 Function keys.1-151.8.4 Title keys.1-171.8.5 Menu key.1-191.8.6 Data screen.1-191.8.7 Setting screen.1-201.8.8 Graph screen.1-211.8.9 History screen.1-221.8.10 Offline mode screen.1-231.8.11 Maintenance screen.1-231.9 Operation of the Major Components.1-241.9.1 Concentrate ports.1-241.9.2 Clamp.1-251.9.3 Blood pump.1-261.9.4 Syringe pump.1-271.9.5 Air detectors.1-281.9.6 Substitution pump(optional).1-301.9.7 Nurse call switch(optional).1-302 Daily Operation.2-22.1 Operation Flow.2-212.2 Operating Procedures.2-32.2.1 Preparing the system for dialysis.2-32.2.2 Installing the dialyzer and the arterial/venous drip chambers.2-32.2.3 Installing the blood line.2-42.2.4 Installing the syringe and priming the syringe pump line.2-42.2.5 Installing the venous line to the air detector and clamp.2-52.2.6 Connecting the pressure lines to the arterial/venous pressure ports.2-62.2.7 Preparing dialysate.2-72.2.8 Setting dialysate.2-82.2.9 Priming the tubing set.2-92.2.10 Gas purge.2-92.2.11 Setting the dialysis parameters.2-102.2.12 Dialysis process.2-102.2.13 Completion of dialysis.2-152.2.14 Blood return.2-152.2.15 Drain.2-152.2.16 Rinsing after the dialysis.2-162.2.17 Completion.2-182.2.18 Pre-rinse.2-192.3 Other Functions.2-212.3.1 Isolated UF.2-212.3.2 Single needle.2-222.3.3 Blood pressure manometer(optional).2-232.3.4 Profile.2-252.3.5 Timer.2-302.3.6 Stopping fluid flow.2-302.4 Setting screen.2-312.4.1 Screen access and setting procedure.2-312.4.2 Dialysate.2-322.4.3 Single needle.2-342.4.4 ArteriaWenous pressure alarm.2-352.4.5 Air detector.2-372.4.6 Setting the functions.2-382.4.7 Blood pressure manometer.2-402.4.8 Compensated values.2-412.5 Data Screen.2-442.5.1 Accessing the Data screen.2-442.5.2 Data 1.2-452.5.3 Data 2.2-462.5.4 Data 3.2-472.5.5 Data 4.2-482.5.6 Operation hours.2-4922.6 Rinse Screen.2-552.6.1 Screen access and setting procedure.2-552.6.2 Rinse time.2-562.6.3 Pre-rinse.2-582.7 Offline Mode Screen.2-592.7.1 Screen access and setting procedure.2-592.7.2 Dialysate.2-602.7.3 Sound/Display.2-642.7.4 Priming.2-652.7.5 Function 1.2-662.7.6 Function 2.2-682.7.7 Rinse.2-702.7.8 Machine Adjustment.2-713 Alarms and Actions.3-23.1 Types of Alarms(Notices).3-23.1.1 System alarms.3-23.1.2 Alarms.3-23.1.3 Notice.3-33.2 How to Reset Alarms.3-43.2.1 The Recover alarm.3-43.2.2 The Interlock alarm.3-43.2.3 The Lock alarm.3-43.2.4 Notice.3-43.3 Alarm Table.3-53.4 Actions to Take in the Event of a Power Failure.3-723.4.1 When a battery is not installed.3-723.4.2 When a battery(optional)is installed.3-733.5 If you require help.3-743.5.1 Emergency shutdown.3-744 Maintenance and Inspection.4-24.1 Daily Maintenance.4-24.1.1 Cautions for maintenance.4-24.1.2 System body.4-24.1.3 Blood leak detector.4-34.1.4 Concentrate port.4-34.2 Storage.4-44.2.1 Storage conditions.4-434.2.2 Storage environment.4-44.2.3 Charging the battery(optional).4-44.3 Daily Inspection.4-54.3.1 Daily inspection items.4-54.4 Periodic Inspection.4-74.4.1 Frequency and items of periodic inspection.4-74.4.2 Periodic replacement parts.4-74.5 About Our After-Sales Services.4-84.5.1 Calling for repair services.4-84.6 Disposal of the System.4-85 Flowchart.5-24IntroductionThank you very much for purchasing our Single Patient Dialysis System.This system is single patient dialysis system intended for hemodialysis treatment of ESRD patients and should not be used for other purposes.This Operation Manual describes requirements for correct and safe use of the system and is not intended as a guide for performing patient treatment or management.Before attempting to use the system,please read this manual carefully to thoroughly understand its correct and safe operation.Keep this Operation Manual in a safe place so as not to lose it.If the manual is lost,please contact your distributor.Information contained in this manual is subject to change.The product can be degraded or worn over time,which may cause an accident under some circumstances.In order to avoid this,be sure to conduct daily inspection and maintenance as well as periodic inspection.Daily inspection should be performed before each use(See Chapter 4).For details on periodic inspection,please contact your distributor.For the periodic inspection procedure,refer to the separate Periodic Inspection Manual.This system may be used only by properly qualified personnel having received proper education and training under the instructions of a physician thoroughly familiar with the patients condition.Adjustment and repair of this system should be performed by personnel having received proper education and training provided by the manufacturer or distributor according to the procedure described in the Service Manual.5For safe use of the systemContraindications Do not use the system near equipment that emits strong electromagnetic waves or noise such as an MRI device,micro wave surgical unit,radiation device(e.g.X-ray device or CT scanner)and an electrocautery device.Do not use tubing sets with a non-specified size.Use of a tubing set with a non-specified size prevents guaranteed performance of the blood pump,substitution pump and air detectors and may result in a medical accident.The system must not be used for purposes other than hemodialysis.Use the arterial air detector(optional)in the arterial segment tubing set and use the substitution fluid air detector(optional)in the substitution fluid segment tubing set.Do not use them in other tubing sets.Failure to follow this instruction may prevent detection of set amounts of air.Ensure that the tube is at least 100 cm in length between the venous air detector and the patient.Otherwise,air may enter into the vessel and cause a patient health hazard.With no explosion prevention provided,this system must not be used in the presence of flammable anesthetics or other substances with possible explosion hazard.Failure to observe this caution may cause an explosion or fire.Use only anticoagulant in the syringe pump.Nothing other than anticoagulant is assumed.Do not use or leave the system in an active gas environment(including disinfection gas)or high humidity environment.With no air-tight construction,the internal electronic parts may be affected and cause failure.Do not use disinfectants or acid cleaning solutions other than those specified Use of non-specified products may damage the system.6Symbols used in this manualThis manual uses the following symbols to indicate items that require the users attention.Warnings and Cautions provide especially important information about safety.Always follow these instructions.Zk WARNINGA warning indicates a situation that involves hazards and requires special attention in the use of this medical device(Non-compliance of the instruction may result in death or severe injury.)cautionA caution indicates a general precaution in the use of this medical device.(Non-compliance to the instruction may result in injury or only damage to property.)CONFIRMCaution is required although it is not likely to cause a hazard described under/LWARNING or zLCAUTION.ManufacturerManufacturing dateSerial number叵Type B applied part大Caution:See Operation Manual before using the system.AThe used system should be disposed of separately form municipal waste.XCautions for Safety小WARNING-Indications for use This system may be used only by personnel having received proper education and training under the instructions of a physician thoroughly familiar with the patienfs condition in accordance with its Operation Manual.Do not cancel the alarm function during treatment.A patient health hazard may be caused.If the alarm function needs to be canceled for some reason,the operator should be responsible for monitoring the system to avoid alarm conditions.The user is responsible for the use and maintenance of the medical equipment.The user must perform daily and periodic inspections.Using the system in an abnormal state may cause a patient health hazard.The exterior of the system is not waterproofed.Do not expose the system to any liquid.Entry of liquid inside the system may cause a patient health hazard due to a malfunction or halt.Monitor the patient,the system and other concurrently used medical equipment at all times.If any abnormal condition is observed,stop the system(machine)in a safe manner for the patient and take any other appropriate actions.In particular,perform a periodic visual check to confirm that all connectors are securely connected to the extracorporeal circuit.For patients with low body weight such as pediatric patients,pay attention to the volumes of extracorporeal circulation,fluid removed and drugs administered.Blood volume must be strictly controlled.Even a small change in blood volume may cause a patient health hazard.For patients with low body weight such as pediatric patients,body temperature must be strictly controlled.Failure to do so may cause a patient health hazard.During treatment,always lock the casters and do not move the system.A patient health hazard may be caused by blood loss due to disconnection of the tubing set or flow rate errors of the pumps.Be sure to select correct dialysate concentrate Incorrect use may result in hemolysis or otherwise cause a patient health hazard.For bicarbonate dialysis,be careful not to confuse A concentrate with B concentrate.A concentrate for acetate dialysis or bicarbonate dialysis:White/Red B concentrate for bicarbonate dialysis:Blue Do not mistake A concentrate(including acetate concentrate)for B concentrate,Disinfectant(sodium hypochlorite solution)or acid cleaning agent(acetic acid).Check the dialyzer-end dialysate line for precipitate formation.Do not use dialysate fluid with precipitate build-up for treatment.8Special attention should be paid to back filtration.Especially,use of a high-performance membrane with large pores may cause an inflammatory reaction or fever due to bacteria or endotoxin contained in dialysate.Also,interdialytic weight gain may result in complications that cause a patient health hazard such as hvoertension,cardiac failure,oericarditis and water intoxication.1Before connecting the tubing set to the patient,confirm the following(hemolysis,air entry or other events may cause a patient health hazard):For each component of dialysate,confirm that its concentration,pH,osmotic pressure and temperature are normal.Confirm that alarm functions for venous pressure and air detectors are normal.After acid cleaning and chemical disinfection using agents,confirm that the equipment is well rinsed with water to remove all residual acid and disinfectant.Confirm that the dialyzer is replaced by dialysate(including Isolated UF mode).When connecting the tubing set and concurrently used medical equipment,pay attention to the following points.Otherwise,a patient health hazard may be caused by hemolysis,coagulation,blood loss due to inability to measure pressure,air entry due to insufficient clamping,or blood loss due to disconnection of the tubing set.Also,this may damage the system and the concurrently used medical equipment.Securely connect the tubing set to the following parts:Air detectors,clamp,blood pump,substitution pump(optional),pressure ports and tube holders Confirm that tubes are firmly interconnected without kinks,bending,pulling or protrusions.Confirm there is no damage or dirt.Always use a hydrophobic air filter at each pressure port of the system.Be sure to use a new filter if hydrophobic air filters are not provided with the tubing set.Also,observe the following cautions.Otherwise,a patient health hazard may be caused by cross infection,or hemolysis,coagulation,blood loss or other anomalies resulting from inability to measure pressure.If the pressure port is contaminated due to damage to the hydrophobic air filter,inspect and disinfect the internal pressure tubes before use.If the hydrophobic air filter gets wet with blood or fluid,replace it immediately.For syringes to be used,follow the precautions below.Otherwise,desired injection speeds will not be obtained and a patient health hazard may be caused.Confirm that the length between the 0-mL and 10-mL marks of the syringe to be used corresponds to that displayed on the screen.Alarms should be set to appropriate values according to the actual operating conditions under a physicians instructions.In particular,the settings for the venous pressure lower limit alarm should satisfy the following requirements.Failure to follow this instruction may cause blood loss or otherwise cause a patient health hazard.Able to detect blood loss due to disconnection of the venous blood line.Able to detect a decrease in the blood flow rate due to coagulation.During treatment,do not touch the system or concurrently used medical equipment carelessly.Failure to follow this caution may cause false operation and cause a patient health hazard.9While the blood pump,syringe pump and substitution pump(optional)are running,be sure to open or close the tubing as required by using tubing forceps or other appropriate tools.Otherwise,intended blood flow rates are not obtained and a patient health hazard may be caused.Also,this system and the concurrently used medical equipment may be damaged.When running the blood pump at an especially low speed,be careful to prevent coagulation.A patient health hazard may be caused.Before using this system,confirm the contents of the initial settings.Do not use the system in a condition in which the tubing set may cause extremely negative or positive pressure.Using the system in such condition will not assure precise flow rate control and a patient health hazard may be caused.When air detection alarm has occurred,observe the following cautions Air may enter into the patients body:Do not turn OFF the power switch.Do not turn the system OFF from the menu window.To avoid entry of air into vessels when the clamp is opened,use a forceps to clip the part of the blood tubing set below the clamp.If air bubbles are produced or have entered,or if any abnormality is found such as blood leakage,coagulation and hemolysis,take appropriate actions in such a way as to ensure patient safety.During blood return,do not turn OFF the air detectors.Air may enter into the patient body.During priming and rinsing of the dialyzer and the blood line,be sure no air is left inside the dialyzer and the tubi
    展开阅读全文
    提示  咨信网温馨提示:
    1、咨信平台为文档C2C交易模式,即用户上传的文档直接被用户下载,收益归上传人(含作者)所有;本站仅是提供信息存储空间和展示预览,仅对用户上传内容的表现方式做保护处理,对上载内容不做任何修改或编辑。所展示的作品文档包括内容和图片全部来源于网络用户和作者上传投稿,我们不确定上传用户享有完全著作权,根据《信息网络传播权保护条例》,如果侵犯了您的版权、权益或隐私,请联系我们,核实后会尽快下架及时删除,并可随时和客服了解处理情况,尊重保护知识产权我们共同努力。
    2、文档的总页数、文档格式和文档大小以系统显示为准(内容中显示的页数不一定正确),网站客服只以系统显示的页数、文件格式、文档大小作为仲裁依据,个别因单元格分列造成显示页码不一将协商解决,平台无法对文档的真实性、完整性、权威性、准确性、专业性及其观点立场做任何保证或承诺,下载前须认真查看,确认无误后再购买,务必慎重购买;若有违法违纪将进行移交司法处理,若涉侵权平台将进行基本处罚并下架。
    3、本站所有内容均由用户上传,付费前请自行鉴别,如您付费,意味着您已接受本站规则且自行承担风险,本站不进行额外附加服务,虚拟产品一经售出概不退款(未进行购买下载可退充值款),文档一经付费(服务费)、不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。
    4、如你看到网页展示的文档有www.zixin.com.cn水印,是因预览和防盗链等技术需要对页面进行转换压缩成图而已,我们并不对上传的文档进行任何编辑或修改,文档下载后都不会有水印标识(原文档上传前个别存留的除外),下载后原文更清晰;试题试卷类文档,如果标题没有明确说明有答案则都视为没有答案,请知晓;PPT和DOC文档可被视为“模板”,允许上传人保留章节、目录结构的情况下删减部份的内容;PDF文档不管是原文档转换或图片扫描而得,本站不作要求视为允许,下载前可先查看【教您几个在下载文档中可以更好的避免被坑】。
    5、本文档所展示的图片、画像、字体、音乐的版权可能需版权方额外授权,请谨慎使用;网站提供的党政主题相关内容(国旗、国徽、党徽--等)目的在于配合国家政策宣传,仅限个人学习分享使用,禁止用于任何广告和商用目的。
    6、文档遇到问题,请及时联系平台进行协调解决,联系【微信客服】、【QQ客服】,若有其他问题请点击或扫码反馈【服务填表】;文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“【版权申诉】”,意见反馈和侵权处理邮箱:1219186828@qq.com;也可以拔打客服电话:0574-28810668;投诉电话:18658249818。

    开通VIP折扣优惠下载文档

    自信AI创作助手
    关于本文
    本文标题:旭化成血透机MDS101_使用手册.pdf
    链接地址:https://www.zixin.com.cn/doc/12592111.html
    页脚通栏广告

    Copyright ©2010-2026   All Rights Reserved  宁波自信网络信息技术有限公司 版权所有   |  客服电话:0574-28810668    微信客服:咨信网客服    投诉电话:18658249818   

    违法和不良信息举报邮箱:help@zixin.com.cn    文档合作和网站合作邮箱:fuwu@zixin.com.cn    意见反馈和侵权处理邮箱:1219186828@qq.com   | 证照中心

    12321jubao.png12321网络举报中心 电话:010-12321  jubao.png中国互联网举报中心 电话:12377   gongan.png浙公网安备33021202000488号  icp.png浙ICP备2021020529号-1 浙B2-20240490   


    关注我们 :微信公众号  抖音  微博  LOFTER               

    自信网络  |  ZixinNetwork