CT成像原理介绍(英文版)复习过程.ppt
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- CT 成像 原理 介绍 英文 复习 过程
- 资源描述:
-
按一下以編輯母片標題樣式,按一下以編輯母片,第二層,第三層,第四層,第五層,*,CT成像原理介绍(英文版),X-Ray Discovery,X-ray was discovered by a German scientist Roentgen 100 years ago.,This made people for the first time be able to,view the anatomy structure of,human body without operation,But its superimposed,And we couldnt view soft tissue,My name is Godfrey Hounsfield,I work for the Central Research,Labs.of EMI,Ltd in England,I developed the the first clinically,useful CT scanner in 1971,History of Computed Tomography,Early 1970s,1963-Alan Cormack developed a mathematical method of reconstructing images from x-ray projections,For the first time we could view:,CT Broke the Barrier,-Tomographic or“,Slice,”anatomy-Density difference,But its time consuming,And resolution needs to be improved,Concept of X-ray Attenuation,An X-ray beam passing through,the body is attenuated(loses its,energy)by:,Absorption,Scattering,Incident X-ray,Transmitted ray,SCATTERED X-RAYS,BODY,TISSUE,Absorption by the tissue is proportional to the density,Less,dense,tissue,More,dense,tissue,MORE ATTENUATION,LESS ATTENUATION,How does CT Work?,Recon.&postpro.,Data acquisition,X-ray generation,X-ray goes through,collimator therefore,penetrate only an axial,layer of the object,called,slice,How does CT Work?,Patient is placed in the center of the measurement field,X-ray is passed through the patients slice from many direction along a 360 path,The transmitted beams are captured by the detectors which digitizes these signals,These digitized signals called raw data are sent to a computer which create the CT image,How does CT Work?,The object slice is divided into small volume elements called voxels.,Each voxel is assigned a value which is dependent on the average amount of attenuation,How is CT Image generated?,The attenuation values are transferred to the computer where they are coded&used to create a slice image,How is CT Image generated?,CT Generations&Design,“Generation”,is used to label CT tube-detector designs,3rd Generation Design,Rotating tube&detector,4th Generation Design,Fixed ring detector,Slip-ring Technology,Power is transmitted through parallel sets of conductive rings,instead of electrical cables,Continuous Gantry Rotation,Prerequisite for Spiral CT,Non Slip-ring Scanner,Slip-ring Scanner,Computed Tomography,CT Basics,Principle of Spiral CT,Scan Parameter&Image Quality,Optimizing Injection Protocols,Clinical Applications,What is Spiral Scan?-just,4“C”,C,ontinuously rotating tube/detector system,C,ontinuously generating X-ray,C,ontinuously table feed,C,ontinuously data acquisition,Reconstruction of arbitrary,slices(either contiguous or,overlapping)within the,scanned volume,Distance between the,slices is called Increment,A,B,Volume Data,Continuous data acquisition,Increment,Slice Thickness,Increment=Slice Thickness,No Overlap,No Gaps,Contiguous Image Reconstruction,Increment,Overlap,Slice,Thickness,Overlapping Image Reconstruction,Increment Slice Thickness,Gaps between slices,Images are further apart,Less images created,Image Reconstruction with Gaps,Increment,Slice Thickness,Standard CT/Slice Imaging,Deep Inspiration,Shallow Inspiration,Misregistration due to different,respiratory levels between slices,Partial Volume Effect,Unable to resconstruct images at,arbitrary position,Slice imaging is slow,Scan the whole region of,interest in one breath hold,Reconstruction of overlapping,images without additional dose,Retrospective reconstruction,of slices in arbitrary position,within the scanned volume,No gaps since radiation always,transmits the whole volume,Spiral CT/Volume Imaging,Computed Tomography,CT Basics,Principle of Spiral CT,Scan Parameter&Image Quality,Optimizing Injection Protocols,Clinical Applications,Scan Parameters,X-ray Tube Voltage,(kVp),X-ray Tube Current,(mA),Scan Time,(s),Slice thickness or Collimation,(mm),Table Speed(,mm/rot),or Feed per 360 rotation,Pitch,Interpolation Process,Increment(mm),Table Speed&Pitch,Table Speed,is defined as distance traveled in mm,per 360 rotation,Pitch,=,Table Feed per rotation,Collimation,10mm P1,10mm P2,30s,30s,More Coverage in,the same time with extended Pitch!,Pitch 2 covers 2x,distance as Pitch 1,Scan Range=300,mm,10mm P1,10 mm/s,10mm P2,20 mm/s,30s,15s,Cover the same volume in shorter time with extended Pitch,To reduce artifacts due to table motion during spiral scanning,we use a special reconstruction process called,INTERPOLATION,Interpolation,Converts volume data into slice images,Interpolation Algorithm,Wide Algorithm,Slim Algorithm,2 x 360,=720,raw data,2(180+52),=464,raw data,Wide algorithm produces a broader image thickness,Wide algorithm uses more raw data=less image noise,PITCH 2,PITCH 1,Pitch 2 scanning produces a broader image thickness,Pitch 2 scanning does not increase image noise,30%increase in,image thickness,with Pitch 2,Slice Sensitivity Profile(SSP),SSP describes the,effective slice thickness,of an image and to what extent anatomy within that slice contribute to the signal,SSP,RESOLUTION,All points within the slice contribute equally,&,points outside of the slice do not contribute to the image at all.,Image signal,Ideal SSP,Z-axis(mm),Collimation=width of x-ray beam=slice profile,Slice Profile(SP),Effective slice thickness of an image,Slice ProfileResolution,Factors influencing Slice Profile,Collimation,Pitch,Interpolation algorithm(360 or 180),Factors influencing SSP,Collimator width,collimation=SSP,Spiral CT,Table speed or Pitch,Interpolation Algorithm,=mathematical process required to reconstruct axial images from the spiral volume data set,Pitch,&,Slice Profile,Slim vs Wide SSP Comparison,Slice Profile Slim%Broaden Wide%Braden,Pitch One 5.0 mm 0 6.3 mm 26,Pitch Two 6.5 mm 30 10.8 mm 116,WIDE,720 degree,More photons,SLIM,464 degree,Less photons,SSP,Spatial,resolution,SSP,Spatial,resolution,Smoother image,Noisier image,Slim-Advantages,Improved Z Resolution,Reduced partial volume artifacts,Slim+extended Pitch,Longer coverage,Same coverage with shorter scan time or thinner slices,Less radiation dose,Wide-Advantages,Noise Reduction,Smoother image,Useful for scanning huge patient,Only for scanning at,Pitch One,Slice Profile Comparison,Lesion smaller than 1cm,SCAN RANGE=150,mm,10/10/10,(15s),5/10/5,(15s),Slice Profile=10,mm,Slice Profile=6.5,mm,Optimizing the Scanning Parameters,Smallest Possible Effective Slice Thickness,Scan Length(mm),Scan Duration(s),Table Speed(mm/s),Smallest,Collimation,(mm),Scan Duration,Depends on the scan length&patients,breath-hold compliance,Table Speed,Pitch Factor,1 Pitch 2,to cover the whole volume in one breath-hold,Computed Tomography,CT Basics,Principle of Spiral CT,Scan Parameter&Image Quality,Optimizing Injection Protocols,Clinical Applications,Peripheral vein eg.antecubital vein,19-20 gauge needle or IV catheter,Volume,Flow Rate,Concentration,Injection Protocols,300 mg I/ml,non-ionic contrast,2-5 ml/s,cardiac output,80-150 ml,patients weight®ion of interest,Site,Scan Delay,Delay between injection initiation&the,start of the scan sequence,Tailoring Scan&Injection Protocols,Injection Duration must be,equal to or greater than,Scan Time,50,100,150,200,250,Times,HU,CONTRAST,50,100,150,200,250,Times,HU,CONTRAST,NaCl,Bolus Duration scan time,Insufficient,inhomogeneous,opacification,Bolus Duration=scan time,Uniform,maximum opacification,Enhancement Curve of the Target Region,50,100,150,200,250,Times,HU,Optimal Window,Early,Time-density curve,of the target region,Late,Contrast Bolus Timing,Determines optimal scan delay for spiral CTA sequence,CONTRAST,NaCl,Test Bolus Procedure,Imaging Volume,for spiral CTA,10-20 ml of contrast is injected,at the chosen rate for spiral,After a delay of 8-10s,low-dose,single-level axial images are,acquired every 2s at the starting,point of the imaging volume,Dynamic scans at,this position,Dynamic Evaluation to generate,a Time-density curve,D,ynamic,E,valuation,Time-density curve,Scan Delay,Peak Enhancement Time,Dynamic Scans,ROI placed in the Aorta,Computed Tomography,CT Basics,Principle of Spiral CT,Scan Parameter&Image Quality,Optimizing Injection Protocols,Clinical Applications,Arterial Phase,Venous Phase,Dual Phase Liver Exam,Liver Metastases,Single Plane Imaging with Multiplanar Results,2D reconstruction based on a serial,of axial images along a certain axis,Sagittal,Coronal,Oblique recon.of Aorta,CT,A,ngiography,Spine 3D image:AVM,Max.Intensity,Projection,Surface Shaded,Display(3D),Femoral Arteries CT Angiogram,3D,Post-processing,3D,Bronchoscopy,Lesion in the right upper lobe branch,Colour Segmentation 3D,Volume Rendering Technique,Transparent image,Transparent&color image,Solid Image,Virtual Endoscopy,Real Time Fly through,Reverse Perspective,Axial Image reference,High Resolution,Bronchoscopy,The END,此课件下载可自行编辑修改,仅供参考!感谢您的支持,我们努力做得更好!谢谢,展开阅读全文
咨信网温馨提示:1、咨信平台为文档C2C交易模式,即用户上传的文档直接被用户下载,收益归上传人(含作者)所有;本站仅是提供信息存储空间和展示预览,仅对用户上传内容的表现方式做保护处理,对上载内容不做任何修改或编辑。所展示的作品文档包括内容和图片全部来源于网络用户和作者上传投稿,我们不确定上传用户享有完全著作权,根据《信息网络传播权保护条例》,如果侵犯了您的版权、权益或隐私,请联系我们,核实后会尽快下架及时删除,并可随时和客服了解处理情况,尊重保护知识产权我们共同努力。
2、文档的总页数、文档格式和文档大小以系统显示为准(内容中显示的页数不一定正确),网站客服只以系统显示的页数、文件格式、文档大小作为仲裁依据,个别因单元格分列造成显示页码不一将协商解决,平台无法对文档的真实性、完整性、权威性、准确性、专业性及其观点立场做任何保证或承诺,下载前须认真查看,确认无误后再购买,务必慎重购买;若有违法违纪将进行移交司法处理,若涉侵权平台将进行基本处罚并下架。
3、本站所有内容均由用户上传,付费前请自行鉴别,如您付费,意味着您已接受本站规则且自行承担风险,本站不进行额外附加服务,虚拟产品一经售出概不退款(未进行购买下载可退充值款),文档一经付费(服务费)、不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。
4、如你看到网页展示的文档有www.zixin.com.cn水印,是因预览和防盗链等技术需要对页面进行转换压缩成图而已,我们并不对上传的文档进行任何编辑或修改,文档下载后都不会有水印标识(原文档上传前个别存留的除外),下载后原文更清晰;试题试卷类文档,如果标题没有明确说明有答案则都视为没有答案,请知晓;PPT和DOC文档可被视为“模板”,允许上传人保留章节、目录结构的情况下删减部份的内容;PDF文档不管是原文档转换或图片扫描而得,本站不作要求视为允许,下载前可先查看【教您几个在下载文档中可以更好的避免被坑】。
5、本文档所展示的图片、画像、字体、音乐的版权可能需版权方额外授权,请谨慎使用;网站提供的党政主题相关内容(国旗、国徽、党徽--等)目的在于配合国家政策宣传,仅限个人学习分享使用,禁止用于任何广告和商用目的。
6、文档遇到问题,请及时联系平台进行协调解决,联系【微信客服】、【QQ客服】,若有其他问题请点击或扫码反馈【服务填表】;文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“【版权申诉】”,意见反馈和侵权处理邮箱:1219186828@qq.com;也可以拔打客服电话:0574-28810668;投诉电话:18658249818。




CT成像原理介绍(英文版)复习过程.ppt



实名认证













自信AI助手
















微信客服
客服QQ
发送邮件
意见反馈



链接地址:https://www.zixin.com.cn/doc/12059302.html